OUT
OUT
230 V
A2
A1
EARTH
NEUTRAL (N)
PHASE (L)
VALID
VALID
Outlet: heating connection
An outlet is a dry contact and does not supply any voltage.
1 - Connect the cables in accordance with the chosen diagram.
2 - Start the secured
Install menu
(from the main menu, simultaneously hold down
Esc
and
Valid
for 3 secs. A star appears
in the top right corner of the home screen).
3 - On the
Outlets / S1-S2-S3
sub-menu (in accordance with chosen terminal), select
HEATING PUMP
to indicate that a
heating pump (any kind) has been connected to the corresponding outlet
.
4 - Via
Temperature menu > Heating pump
:
> Select
OFF
to cut off the heating pump.
> Select
AUTO
to ensure that the temperature is controlled automatically. A menu
Setpoint
will then appear. > Select
Setpoints
to change the target value. A menu
Priority
will then appear. > Select
Priority
to activate or not. The priority will
activate the filtration and heating pump, even if filtration has been stopped. Do not activate the priority when the heating pump
has been activated, unless the filtration is running for another reason.
5 - Via
Temperature menu > Calibration
: Manual correction of the temperature concerned. Enables adjustment of temperature,
using another thermometer as a reference.
6 - Via
Temperature menu > Anti freeze
: Temperature where filtration is forced to prevent the pool from freezing. The heating
pump is not used for anti freeze protection.
Connection
via a contactor
Connection
via the safety shutdown
(flow switch)
-Heating pump
Calibration
Antifreeze : +3°C
-Heating pump: AUTO
Set point : 30°C
Priority : NO
CALIBRATION
-Temp. Water:+23.2°C
-Temp. Air :+23.3°C