STANDARD LIMITED WARRANTY

Pentair Hydromatic

®

 warrants its products against defects in material and workmanship for a period of 12 months 

from the date of shipment from Pentair Hydromatic or 18 months from the manufacturing date, whichever  

occurs first – provided that such products are used in compliance with the requirements of the Pentair Hydromatic  

catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive-free,  

noncorrosive liquids. 

during the warranty period and subject to the conditions set forth, Pentair Hydromatic, at its discretion, will repair 

or replace to the original user, the parts that prove defective in materials and workmanship. Pentair Hydromatic 

reserves the right to change or improve its products or any portions thereof without being obligated to provide such 

a change or improvement for prior sold and/or shipped units.

Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of start up 

through the Pentair Hydromatic website: http://forms.pentairliterature.com/startupform/startupform.asp?type=h.  

Warranty is effective only if Pentair Hydromatic authorized control panels are used. All seal fail and heat sensing 

devices must be hooked up, functional and monitored or this warranty will be void. Pentair Hydromatic will cover 

only the lower seal and labor thereof for all dual seal pumps. under no circumstance will Pentair Hydromatic be 

responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight 

expenses to and from the factory or an authorized Pentair Hydromatic service facility.
This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or 

maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident 

or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that 

are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is 

moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and 

manufactured; (g) to any unit that has been repaired or altered by anyone other than Pentair Hydromatic or an 

authorized Pentair Hydromatic service provider; (h) to any unit that has been repaired using non factory specified/

oEM parts.

Warranty Exclusions: PEnTAiR HYdRoMATiC MAKES no EXPRESS oR iMPLiEd WARRAnTiES THAT EXTEnd 

bEYond THE dESCRiPTion on THE FACE HEREoF. PEnTAiR  HYdRoMATiC SPECiFiCALLY diSCLAiMS THE 

iMPLiEd WARRAnTiES oF MERCHAnTAbiLiTY And FiTnESS FoR AnY PARTiCuLAR PuRPoSE.

Liability Limitation: in no EVEnT SHALL PEnTAiR  HYdRoMATiC bE LiAbLE oR RESPonSibLE FoR 

 

ConSEQuEnTiAL, inCidEnTAL oR SPECiAL dAMAGES RESuLTinG FRoM oR RELATEd in AnY MAnnER To  

AnY  PEnTAiR  HYdRoMATiC PRoduCT oR PARTS THEREoF. PERSonAL inJuRY And/oR PRoPERTY dAMAGE  

MAY RESuLT FRoM iMPRoPER inSTALLATion. PEnTAiR  HYdRoMATiC diSCLAiMS ALL LiAbiLiTY, inCLudinG 

LiAbiLiTY undER THiS WARRAnTY, FoR iMPRoPER inSTALLATion. PEnTAiR  HYdRoMATiC RECoMMEndS 

inSTALLATion bY PRoFESSionALS.

Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or 

consequential damages and therefore such limitations may not apply to you. no warranties or representations at any 

time made by any representatives of Pentair Hydromatic shall vary or expand the provision hereof.

Summary of Contents for Hydromatic NOVUS 3000 Series

Page 1: ... provide this manual to the owner of the equip ment or to the responsible party who maintains the system NOVUS 3000 STANDARD ELECTRICAL CONTROLS INSTALLATION AND SERVICE MANUAL Item H 03 519 Part 5625 519 1 2012 Pentair Pump Group Inc 11 02 12 ...

Page 2: ...dicator lights and external relay drivers for the following conditions floats out of order seal fail for pumps 1 and 2 temperature fail for pumps 1 and 2 and pump disabled for pumps 1 and 2 Unpacking Panel Remove panel from carton When un pack ing unit check for con cealed damage Claims for damage must be made at the receiving end through the delivery carrier Dam age cannot be processed from the f...

Page 3: ...mally open float switches for level sensing When the tank is empty all of the floats are open The lowest float is the low alarm float If it is not used the low float input should be shorted with a jumper When the tank is empty the controller will be in the low alarm condition On rising water when the level is high enough to close the low float switch then the low alarm will go off As the level ris...

Page 4: ...is run ning Check for flow On three phase power check to see if each pump has prop er ro ta tion Wrong ro ta tion will give low flow 8 Check full load current with amp probe and compare it with the name plate rat ing On three phase pumps check all three phases On single phase pumps check black pump lead 9 Check operation of start relay if supplied on single phase panels per procedure in Item 7ofMa...

Page 5: ...es the resistance of the sensor In normal operation the seal fail condition is set if the resistance is less than 2000 ohms One of the option switches can be used to change this to set the alarm if the resistance is greater than 2000 ohms If a seal fail alarm is set then that pump is demoted to lag pump and its seal fail lamp and output are activated The seal fail does not disable the pump Each pu...

Page 6: ...er or telemetry system There are six switches on the back of the controller which select several different options SW1 When this switch is set the fail to start test is enabled SW2 When this switch is set the temperature fail condition is latched up until reset SW3 When this switch is set the seal fail input is inverted open is fault SW4 When this switch is set the aux relay is the common alarm If...

Page 7: ...inuous sink current 0 4 amps Maximum on resistance 2 ohms WARNING Before handling thesepumpsandcontrols always dis con nect the power first Do not smoke or use sparkable electrical devices or flames in a septic gas eous or possible septic sump 1 Pump does not run in Hand position a Check pump circuit breaker and control fuse for trip ping or blown condition b Check incoming power volt age and cont...

Page 8: ... miswired to ter mi nal block e Voltage and current unbalance Three phase only Voltage un bal ance on three phase power sources can cause motor current to become un bal anced and exces sive heating will re sult Trip ping of the over load protectors and premature motor failures can be expected if the current unbalance exceeds five percent Percent Maximum Current Current Difference from x 100 Unbala...

Page 9: ... lead c Set the amp meter scale to at least 2 times the pump motor full load current d Place the H O A switch in the Hand position to start the pump e The meter should read ap prox i mate ly 2 times full load current during starting f After the motor has started within one sec ond the cur rent should drop to a value much less than full load cur rent 5 Motor voltage check Typical Motor Voltage Comp...

Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 11: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 12: ...o and from the factory or an authorized Pentair Hydromatic service facility This limited warranty will not apply a to defects or malfunctions resulting from failure to properly install operate or maintain the unit in accordance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such ser...

Reviews: