7000XTR Service Manual
Control Valve
WARNING:
The controller MUST be depressurized before
removing any quick connection clips for
servicing. The connector should be pushed
toward the control while removing clips.
Problem
Cause
Correction
Water conditioner fails to
regenerate.
Electrical service to unit has been interrupted Assure permanent electrical service (check fuse, plug,
pull chain, or switch)
Timer is defective.
Replace timer.
Power failure.
Reset time of day.
Hard water.
By-pass valve is open.
Close by-pass valve.
No salt is in brine tank.
Add salt to brine tank and maintain salt level above
water level.
Injector screen plugged.
Clean injector screen.
Insufficient water flowing into brine tank.
Check brine tank fill time and clean brine line flow
control if plugged.
Hot water tank hardness.
Repeated flushings of the hot water tank is required.
Leak at distributor tube.
Make sure distributor tube is not cracked. Check o-ring
and tube pilot.
Internal valve leak.
Replace seals and spacers and/or piston.
Unit used too much salt.
Improper salt setting.
Check salt usage and salt setting.
Loss of water pressure.
Iron buildup in line to water conditioner.
Clean line to water conditioner.
Iron buildup in water conditioner.
Clean control and add mineral cleaner to mineral bed.
Increase frequency of regeneration.
Inlet of control plugged due to foreign
material broken loose from pipes by recent
work done on plumbing system.
Remove piston and clean control.
Loss of mineral through drain line.
Air in water system.
Assure that well system has proper air eliminator
control. Check for dry well condition.
Improperly sized drain line flow control.
Check for proper drain rate.
Iron in conditioned water.
Fouled mineral bed.
Check backwash, brine draw, and brine tank fill.
Increase frequency of regeneration. Increase
backwash time.
Excessive water in brine tank.
Plugged drain line flow control.
Clean flow control.
Plugged injector system.
Clean injector and screen.
Timer not cycling.
Replace timer.
Foreign material in brine valve.
Replace brine valve seat and clean valve.
Foreign material in brine line flow control.
Clean brine line flow control.
Softener fails to draw brine.
Drain line flow control is plugged.
Clean drain line flow control.
Injector is plugged.
Clean injector
Injector screen plugged.
Clean screen.
Line pressure is too low.
Increase line pressure to 20 psi (1.3 bar)
Internal control leak
Change seals, spacers, and piston assembly.
Service adapter did not cycle.
Check drive motor and switches.
Control cycles continuously.
Misadjusted, broken, or shorted switch.
Determine if switch or timer is faulty and replace it, or
replace complete power head.
Drain flows continuously.
Valve is not programming correctly.
Check timer program and positioning of control. Replace
power head assembly if not positioning properly.
Foreign material in control.
Remove power head assembly and inspect bore.
Remove foreign material and check control in various
regeneration positions.
Internal control leak.
Replace seals and piston assembly.
TROUBLESHOOTING
CONTINUED
Summary of Contents for FLECK 7000XTR
Page 1: ...www pentairaqua com FLECK 7000XTR SERVICE MANUAL...
Page 7: ...FLECK 7000XTR Service Manual 7 MASTER PROGRAMMING MODE FLOW CHART CONTINUED...
Page 13: ...FLECK 7000XTR Service Manual 13 CONTROL VALVE ASSEMBLY 61500 7000EXP REV C...
Page 23: ...FLECK 7000XTR Service Manual 23 INJECTOR FLOW DATA TR18755 REV B...