DIAGNOSTIC PROGRAMMING MODE

NOTE:   Depending on current option settings, some displays 

cannot be viewed.

Overview Diagnostic Mode

The current Diagnostic Programming Mode screen will display 

until either the Extra Cycle button is pressed through for each 

screen, or the Diagnostic button is pressed. In the event of 

regeneration occurring while in the Diagnostic Programming 

Mode, the regeneration step and time remaining will be 

displayed. When regeneration completes, the display will 

return to the normal time of day display screen.

Entering and Exiting Diagnostic Mode

Press and release the “D” button to enter the Diagnostic 

Programming Mode. Pressing the Extra Cycle button will move to 

the next diagnostic screen. Press the Extra Cycle button once per 

display until all are viewed. Pressing the Diagnostic button while 

in Diagnostic Mode will cause the unit to leave the Diagnostic 

Mode and return to the normal time of day display screen.

1. Current Flow Rate

This program step displays the calculated flow rate for the 

timer. The below flow rates are the maximum flow rate the 

timer will read for each meter. 
1.25 inch Turbine: 90 gpm (0.34 m

3

/m)

•  Press the Extra Cycle button.

2. Peak Flow Rate

This program step displays the peak flow rate (1 minute 

average) since the last regeneration.

•  Press the Extra Cycle button.

3. Totalizer

This program step displays the total volume of treated water 

that passes through the meter.

•  Reset to zero by holding the Up and Down buttons for five 

seconds while in the totalizer screen.

•  Press the Extra Cycle button.

4. Hours Between Last Two Regenerations

This program step displays the time between the last two 

regenerations saved. 

•  Press the Extra Cycle button.

5. Hours Since Last Regeneration

This program step displays the hours since the last regeneration.  

•  Press the Extra Cycle button.

6. Volume Remaining

This program step displays the volume remaining. The timer 

will regenerate if the volume remaining is set to zero. The 

maximum ranges are the same as the maximum volume 

calculated on the main screen.

•  Press the Extra Cycle button.

7. Reserve Capacity

This program step displays the reserve capacity, ensuring soft 

water is available at all times. 

•  Press the Extra Cycle button.

8. Previous Day’s Water Usage

This program step displays the previous day’s water usage. 

•  Press the Extra Cycle button.

9. Software Version

This program step displays the timer’s software program 

version number. 

•  Press the Extra Cycle button to exit.

NOTE:   Diagnostic Programming Mode will stop if the system 

goes into a regeneration.

Summary of Contents for FLECK 7000XTR

Page 1: ...www pentairaqua com FLECK 7000XTR SERVICE MANUAL...

Page 2: ...be installed by a plumbing professional This unit is designed to be installed on potable water systems only This product must be installed in compliance with all state and municipal plumbing and elect...

Page 3: ...ss __________Grains French Degrees German Degrees PPM 7 Capacity Safety Factor A Zero B __________ 8 Volume Override __________ Gallons or M3 9 Regeneration Day Override A Off B Every__________Days 10...

Page 4: ...to local plumbing codes 3 Cut the 1 05 inch 2 6 cm distributor tube flush with the top of the tank A Deburr the outside of the tube B after cutting Lubricate the o ring C with non petroleum based grea...

Page 5: ...eration time has been reached Meter Delayed Weekly Reserve A Volume remaining has been depleted to the weekly variable reserve volume and B the regeneration time has been reached Volume Override Immed...

Page 6: ...ay Regeneration Day Override Feature If the Day Override option is turned on and the valve reaches the set Regeneration Day Override value the Regeneration Cycle starts at the programmed regeneration...

Page 7: ...FLECK 7000XTR Service Manual 7 MASTER PROGRAMMING MODE FLOW CHART CONTINUED...

Page 8: ...tra Cycle button 2 Valve Type This program step selects the valve type Press the Up or Down buttons to adjust this value Press the Extra Cycle button 3 Regenerant Flow This program step selects how th...

Page 9: ...y Output Window Start End Time Setting This option setting consists of two displays The first display sets the turn on time of the output referenced to the start of the first regeneration cycle The se...

Page 10: ...types 3 Set Regeneration Day Override To turn on and set the days press the Down button Press the Shift Up and Down buttons to move the cursor and change the value of the numbers Press the Extra Cycl...

Page 11: ...the Extra Cycle button 2 Peak Flow Rate This program step displays the peak flow rate 1 minute average since the last regeneration Press the Extra Cycle button 3 Totalizer This program step displays t...

Page 12: ...ar Main 7 1 40704 Cam Brine Downflow 8 1 40979 Plate Lower Support 9 1 61635 01 Cover Assy 7000 II Black 1 61634 01 Cover Assy 7000 II Gray 10 1 40980 Backplate 7000 11 4 13602 Screw Phil Rd Hd 6 32 x...

Page 13: ...FLECK 7000XTR Service Manual 13 CONTROL VALVE ASSEMBLY 61500 7000EXP REV C...

Page 14: ...C Assemblies DLFC Size GPM 61455 00 3 4 inch Blank 61455 17 3 4 inch 1 7 61455 20 3 4 inch 2 0 61455 24 3 4 inch 2 4 61455 30 3 4 inch 3 0 61455 35 3 4 inch 3 5 61455 40 3 4 inch 4 0 61455 45 3 4 inch...

Page 15: ...ch BSP w O ring 3 2 41242 01 Connector Assy 1 inch 1 4 inch Sweat w O ring 41243 01 Connector Assy 1 1 4 inch 1 1 2 inch Sweat w O ring 4 2 40576 Clip H Plastic 7000 5 1 40951 O ring 220 Not Shown 1 6...

Page 16: ...LECK 7000XTR Service Manual 2310 SAFETY BRINE VALVE Item No QTY Part No Description 1 1 60014 Safety Brine Valve Assy 2310 2 1 60068 30 Float Assy 2310 w 30 inch Rod 3 1 60002 34 Air Check 500 42112 R...

Page 17: ...Flashing blinking display Power outage has occurred Either wait 5 minutes for blinking to stop or press any key on the keypad Unit not responding after going into regeneration Verify the unit is confi...

Page 18: ...system Remove piston and clean control Loss of mineral through drain line Air in water system Assure that well system has proper air eliminator control Check for dry well condition Improperly sized dr...

Page 19: ...ts and reset reserve capacity to provide additional reserve Meter is not measuring flow On Mechanical Meter Check with meter checker kit If volume is not registering check the meter cap and impeller f...

Page 20: ...REV A 41121 REV A Backwash Position 40988 REV A 41121 REV A Brine Position 40988 REV A 41121 REV A Slow Rinse Position 40988 REV A 41121 REV A Second Backwash Position 40988 REV A 41121 REV A Rapid R...

Page 21: ...t board align notches on left side of board with flexible finger on power head Apply pressure to left while rotating the board back 42554 REV A 2 When all the way down snap the circuit board into plac...

Page 22: ...22 FLECK 7000XTR Service Manual DIMENSIONAL DRAWINGS 61500 7000XTR LNE REV A METER FLOW DATA TR18753 Softener TR18688 Filter 41140 02 REV A...

Page 23: ...FLECK 7000XTR Service Manual 23 INJECTOR FLOW DATA TR18755 REV B...

Page 24: ...emarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pe...

Reviews: