FLECK

 7000XTR Service Manual

Queued Regeneration (RGQ)

From the display screen, while the unit is in service, hold down 

the Extra Cycle button until “RGQ” displays. The valve will 

regenerate when the set regeneration time has been reached.

Timer Operation During Regeneration

In the main display screen, the timer shows the current 

regeneration cycle and the time for that step. The green 

LED light will display when the unit is in regeneration. Once 

all regeneration steps are complete, the timer returns to in 

service, and displays a blue LED light. 

Timer Operation During Programming

The timer enters program mode (unit must be in service). 

While in the program mode the timer continues to operate 

normally, monitoring water usage. Timer programming is 

stored in memory permanently upon a normal exit from 

programming mode.

Timer Operation During A Power Failure

All program settings are stored in permanent memory. 

Current valve position, cycle step time elapsed, and time of day 

are stored during a power failure, and will be restored upon 

power re-application. Time is kept during a power failure, and 

time of day is adjusted upon power up (as long as power is 

restored within 12 hours).

NOTE:   The time of day on the main display screen will flash 

for 5 minutes when there has been a power outage. 

The flashing of the time of day can be stopped by 

pressing any button on the display.

Regeneration Day Override Feature 

If the Day Override option is turned on and the valve reaches 

the set Regeneration Day Override value, the Regeneration 

Cycle starts at the programmed regeneration time.

Flow Meter Equipped Timer

As treated water is used, the Volume Remaining display counts 

down from the calculated system capacity, less the reserve 

volume. Once capacity reaches the reserve volume, the system 

will regenerate based on the set regeneration time. If set for 

an Immediate system, the unit will regenerate immediately 

once it reaches zero capacity. If it is a Fixed, Variable, or 

Weekly reserve, the unit will queue a regeneration (RGQ) and 

count down Reserve Volume until the set regeneration time.

NOTE:   Reserve Volume is only available in a RGQ system.

Volume Remaining 

(Less Reserve)

Reserve Volume

WARNING:

 Transformer must be grounded and ground wire 

must be terminated to the back plate where 

grounding label is located before installation.

TIMER OPERATION 

CONTINUED

MASTER PROGRAMMING MODE FLOW 
CHART

CAUTION

 Before entering Master Programming, please 

contact your local professional water dealer.

NOTE:   Depending on current option settings, some displays 

cannot be viewed or set. 

Entering Master Programming Mode

1.  Press and hold the Shift and Up buttons for 5 seconds.  
2.  Set the Time of Day display to 12:01 P.M. or 12:01HR. Then 

go to the main display screen, press the Up and Down 

buttons at the same time for 5 seconds. 

To Set Time Of Day:

1.  Press and hold the Up 

or

 Down buttons for 2 seconds. 

2.  Press the Shift button to select the digit you want to modify.

Summary of Contents for FLECK 7000XTR

Page 1: ...www pentairaqua com FLECK 7000XTR SERVICE MANUAL...

Page 2: ...be installed by a plumbing professional This unit is designed to be installed on potable water systems only This product must be installed in compliance with all state and municipal plumbing and elect...

Page 3: ...ss __________Grains French Degrees German Degrees PPM 7 Capacity Safety Factor A Zero B __________ 8 Volume Override __________ Gallons or M3 9 Regeneration Day Override A Off B Every__________Days 10...

Page 4: ...to local plumbing codes 3 Cut the 1 05 inch 2 6 cm distributor tube flush with the top of the tank A Deburr the outside of the tube B after cutting Lubricate the o ring C with non petroleum based grea...

Page 5: ...eration time has been reached Meter Delayed Weekly Reserve A Volume remaining has been depleted to the weekly variable reserve volume and B the regeneration time has been reached Volume Override Immed...

Page 6: ...ay Regeneration Day Override Feature If the Day Override option is turned on and the valve reaches the set Regeneration Day Override value the Regeneration Cycle starts at the programmed regeneration...

Page 7: ...FLECK 7000XTR Service Manual 7 MASTER PROGRAMMING MODE FLOW CHART CONTINUED...

Page 8: ...tra Cycle button 2 Valve Type This program step selects the valve type Press the Up or Down buttons to adjust this value Press the Extra Cycle button 3 Regenerant Flow This program step selects how th...

Page 9: ...y Output Window Start End Time Setting This option setting consists of two displays The first display sets the turn on time of the output referenced to the start of the first regeneration cycle The se...

Page 10: ...types 3 Set Regeneration Day Override To turn on and set the days press the Down button Press the Shift Up and Down buttons to move the cursor and change the value of the numbers Press the Extra Cycl...

Page 11: ...the Extra Cycle button 2 Peak Flow Rate This program step displays the peak flow rate 1 minute average since the last regeneration Press the Extra Cycle button 3 Totalizer This program step displays t...

Page 12: ...ar Main 7 1 40704 Cam Brine Downflow 8 1 40979 Plate Lower Support 9 1 61635 01 Cover Assy 7000 II Black 1 61634 01 Cover Assy 7000 II Gray 10 1 40980 Backplate 7000 11 4 13602 Screw Phil Rd Hd 6 32 x...

Page 13: ...FLECK 7000XTR Service Manual 13 CONTROL VALVE ASSEMBLY 61500 7000EXP REV C...

Page 14: ...C Assemblies DLFC Size GPM 61455 00 3 4 inch Blank 61455 17 3 4 inch 1 7 61455 20 3 4 inch 2 0 61455 24 3 4 inch 2 4 61455 30 3 4 inch 3 0 61455 35 3 4 inch 3 5 61455 40 3 4 inch 4 0 61455 45 3 4 inch...

Page 15: ...ch BSP w O ring 3 2 41242 01 Connector Assy 1 inch 1 4 inch Sweat w O ring 41243 01 Connector Assy 1 1 4 inch 1 1 2 inch Sweat w O ring 4 2 40576 Clip H Plastic 7000 5 1 40951 O ring 220 Not Shown 1 6...

Page 16: ...LECK 7000XTR Service Manual 2310 SAFETY BRINE VALVE Item No QTY Part No Description 1 1 60014 Safety Brine Valve Assy 2310 2 1 60068 30 Float Assy 2310 w 30 inch Rod 3 1 60002 34 Air Check 500 42112 R...

Page 17: ...Flashing blinking display Power outage has occurred Either wait 5 minutes for blinking to stop or press any key on the keypad Unit not responding after going into regeneration Verify the unit is confi...

Page 18: ...system Remove piston and clean control Loss of mineral through drain line Air in water system Assure that well system has proper air eliminator control Check for dry well condition Improperly sized dr...

Page 19: ...ts and reset reserve capacity to provide additional reserve Meter is not measuring flow On Mechanical Meter Check with meter checker kit If volume is not registering check the meter cap and impeller f...

Page 20: ...REV A 41121 REV A Backwash Position 40988 REV A 41121 REV A Brine Position 40988 REV A 41121 REV A Slow Rinse Position 40988 REV A 41121 REV A Second Backwash Position 40988 REV A 41121 REV A Rapid R...

Page 21: ...t board align notches on left side of board with flexible finger on power head Apply pressure to left while rotating the board back 42554 REV A 2 When all the way down snap the circuit board into plac...

Page 22: ...22 FLECK 7000XTR Service Manual DIMENSIONAL DRAWINGS 61500 7000XTR LNE REV A METER FLOW DATA TR18753 Softener TR18688 Filter 41140 02 REV A...

Page 23: ...FLECK 7000XTR Service Manual 23 INJECTOR FLOW DATA TR18755 REV B...

Page 24: ...emarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pe...

Reviews: