17
TROUBLESHOOTING
Timer
If an error is detected, an error screen will alternate with the
main display screen every few seconds, and the LED light will
be red.
During an error condition, the unit continues to monitor
the flow meter and update the remaining capacity. Once an
error condition is corrected, the unit returns to the operating
status it was in prior to the error, and regeneration resumes
according to normal programming. If an error is cleared by
reprogramming the unit in the Master Programming Mode,
the volume remaining may be reset to the full unit capacity
(as though it had just regenerated). If an error is present,
a regeneration can only occur manually by pressing and
holding the Extra Cycle button for 5 seconds. If the unit was
in regeneration when the error occurred, it will complete the
regeneration cycle and go into service.
When the problem is corrected, and the error no longer displays
(it may take several seconds for the unit to stop displaying the
error message), the unit will return to normal operation. The
LED light will no longer be red, and will turn Green if the unit is
regenerating, or Blue if the unit is in service.
Problem
Correction
Flashing/blinking
display
Power outage has occurred. Either wait 5
minutes for blinking to stop, or press any
key on the keypad.
Unit not responding
after going into
regeneration
Verify the unit is configured correctly (ex:
wiring valve type). Perform a Master Reset
by holding the Shift button and cycling
power. Check and verify the choices
selected in Master Programming Mode.
Unit displays “ERROR
CODE: REPLACE UNIT”
(corrupted UAP)
Contact your local water treatment
professional.
Error
Code
Display
Message
Correction
01
ERROR CODE:
PROGRAM UNIT
Go through all screens in Master
Programming Mode.
02
ERROR CODE:
PROGRAM UNIT
Go through all screens in Master
Programming Mode.
03
ERROR CODE:
SERVICE UNIT
Perform a Master Reset by holding
the Shift button and cycling power.
Go through all screens in Master
Programming Mode. Manually initiate a
regeneration cycle by pressing the Extra
Cycle button for 5 seconds.
04
ERROR CODE:
SERVICE UNIT
Perform a Master Reset by holding
the Shift button and cycling power.
Go through all screens in Master
Programming Mode. Manually initiate a
regeneration cycle by pressing the Extra
Cycle button for 5 seconds.
05
ERROR CODE:
SERVICE UNIT
Call your local water treatment
professional as soon as possible. Leave
the unit running (do not unplug).
NOTE: If the above corrections do not work, please contact
your local water treatment professional.
Error Display Screen Examples:
Summary of Contents for FLECK 7000XTR
Page 1: ...www pentairaqua com FLECK 7000XTR SERVICE MANUAL...
Page 7: ...FLECK 7000XTR Service Manual 7 MASTER PROGRAMMING MODE FLOW CHART CONTINUED...
Page 13: ...FLECK 7000XTR Service Manual 13 CONTROL VALVE ASSEMBLY 61500 7000EXP REV C...
Page 23: ...FLECK 7000XTR Service Manual 23 INJECTOR FLOW DATA TR18755 REV B...