N. Trim Adjustment
NOTE: The right side panel
must
be removed to
make trim adjustments with the dial control
To see a visual, go to page18 & reference side panel replacement part
The small dial located below the main dial control is used
to adjust the amount of combustion air for the fire. You
may need to adjust the combustion air to the fire for:
Elevation
Venting/Installation Configurations
Fuel Quality
If your fire is too large, lazy, or producing black soot, you
need MORE air. To increase the amount of combus
-
tion air, rotate counterclockwise one level at a time and
allow 15 minutes for stabilization prior to making another
adjustment. If your fire is too small and sometimes goes
out when there are pellets in the hopper, you may have
too much air (too lean). To decrease the amount of
combustion air, rotate clockwise one level at a time and
allow 15 minutes for stabilization prior to making another
adjustment.
J.
Ignition Cycles
1. At the beginning of each ignition cycle, it is normal to see
some smoke in the firebox. The smoke will stop once
the fire starts.
2. The convection blower will automatically turn on after
your appliance has been burning for approximately 10
minutes.
This blower transfers heat from your appliance into the
room, and will continue to run even after the unit has
shutdown. It will turn off after the exhaust temperature
has cooled.
3. Occasionally the appliance may run out of fuel and shut
itself down. When this happens the empty hopper alarm
will be triggered.
WARNING! RISK OF FIRE!
Keep combustible materials,
gasoline and other flammable vapors and liquids clear of
appliance.
• Do
NOT
store flammable materials in the appliance’s
vicinity.
• Do
NOT
use gasoline, lantern fuel, kerosene, charcoal
lighter fluid or similar liquids to start or “freshen up” a fire
in this heater.
Keep all such liquids well away from the heater while it is in
use as combustible materials may ignite.
M. Clear Space
WARNING! RISK OF FIRE!
Do NOT place combustible
objects in front or to the sides of the appliance. High tem-
peratures may ignite clothing, furniture or draperies.
NOTICE:
Clearances may only be reduced by means ap-
proved by the regulatory authority having jurisdiction.
Mantel:
Avoid placing candles and other heat-sensitive
objects on mantel or hearth. Heat may damage these
objects.
K.
Running in Minimum or Maximum
When the dial control is set to run on the LO or HI setting,
the appliance will continue to run without regard to the
actual temperature in the room. The appliance will shut off
only if the dial control is set to a different setting or there is
an error such as an empty hopper.
When running on LO or HI it is important to follow the daily
cleaning activities especially cleaning the firepot. Failure
to do so will reduce the performance of the appliance.
L.
Running in the Comfort Level Mode
When the dial control is set to run in the automatic mode
the unit will adjust the actual burn rate based on the
difference between the room temperature as sensed by
the probe located in the rear of the unit and the desired
comfort level as set on the dial control.
The comfort level range is from 65 degrees Fahrenheit to
82 degrees Fahrenheit.
Once the desired comfort level is achieved the appliance
will automatically shut down and turn off. When the
temperature in the room drops 3 degrees below the
desired comfort level, the appliance will automatically
restart.
CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
PART NAME:
DRAWN BY:
SCALE:
MATERIAL:
SHEET:
PART NUMBER:
REV:
THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING
DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.
ECO #
DATE
BY
REV
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03 (3) PLACE DEC: ± 0.005 ANGLE: ± 2° FRACTION: ± 1/16
OUTSIDE MATERIAL.
NORMAL DIM & INSIDE MATERIAL.
OUTSIDE APEX
INSIDE APEX - DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS
REVISIONS
ITEM
PART NUMBER
PART NAME
QTY
A RELEASED
72906
06/20/13
MCW
LABEL OPERATION AND MAINTENANCE
MCW
NTS
SEE NOTE
1 OF 1
7083-168
A
NOTE:
1. MATERIAL: NON-ANODIZED ALUMINUM 0.020 THICK
2. BACKGROUND: BLACK
3. COPY: SILVER
4. ADHESIVE: 3M #468 PERMANENT ACRYLIC
5. TEMPERATURE RATING: -50°F TO 350°F
RELEASED
-
----
-----
-
6.75
11.75
4X R0.13
2X
Broken Exhaust Probe
Sonde d'échappement cassé
Sonda de escape roto
1X
Empty Hopper
trémie vide
tolva vacía
OFF
3X
Broken Ambient Probe
Cassé la sonde ambiante
Sonda ambiente roto
4X
Failed Ignition
allumage échoué
de encendido no
OFF
8X
High Exhaust Temperature
Température d'échappement haute
Alta temperatura de escape
Troubleshooting
Dépannage / Solución de problemas
Reset From Error
1. Determine error from above table.
2. Correct error condition. (see Owner’s Manual for additional information.)
3. Turn dial control to OFF position, wait 10 seconds.
4. Follow STARTING instructions.
Réinitialisation des erreurs
1. Déterminer l'erreur de tableau ci-dessus.
2. Condition d'erreur correct. (voir le manuel du propriétaire pour plus
d'informations.)
3. Tourner le cadran de commande en position OFF, attendez 10 secondes.
4. Suivez les instructions de démarrage.
Restablecer de error
1. Determinar el error de la tabla anterior.
2. Condición de error correcto. (consulte el Manual del Propietario para
obtener información adicional.)
3. Gire el dial de control en la posición OFF, espere 10 segundos.
4. Siga las instrucciones de arranque.
Customer Service / Service Clients / Servicio al Cliente
877-427-3316
www.pelprostoves.com
Daily / Quotidien / Todos los días
1 Bag / 1 Sac / 1 Bolsa
Empty Firepot / Creuset Vide / Brasero De Fuego Vacía
Clean Firepot / Clean Creuset / Limpieza Brasero De Fuego
Weekly / Hebdomandair / Semanalmente
5 Bags / 5 Sacs / 5 Bolsas
Clean Holes / Nettoyer Les Trous / Limpie Los Orificios
Remove Ash / Retirez Les Cendres / Quitar Las Cenizas
Monthly / Mensuel / Mensualmente
25 Bags / 25 Sacs / 25 Bolsas
1
2
3
Remove / Supprimer / Quitar
Vacuum / Vide / Vacío
Maintenance / Entretien / Mantenimiento
7083-168
Operation / Opération / Operación
Automatic Mode *
mode Automatique
Modo Automático
Priming Fuel
carburant d'amorçage
cebado de combustible
Minimum / Maximum **
minimale / maximale
mínimo / máximo
Starting
1. Turn dial control to OFF position.
2. Fill hopper with pellets.
3. Turn dial control to desired setting.
Départ
1. Tourner le cadran de commande en
position OFF.
2. Remplir la trémie avec des granulés.
3. Tourner le cadran de commande au réglage
désiré.
A partir
1. Gire el dial de control en la posición OFF.
2. Llene la tolva con perdigones.
3. Gire el dial de control hasta la posición deseada.
Stopping
1. Turn dial control to OFF position.
2. Allow unit to cool before performing any maintenance.
Arrêt
1. Tourner le cadran de commande en position OFF.
2. Laissez refroidir avant d'effectuer toute opération de maintenance.
Parada
1. Gire el dial de control en la posición OFF.
2. Deje enfriar la unidad antes de realizar cualquier trabajo de mantenimiento.
* The appliance will automatically maintain the desired comfort level and shut down when level
has been achieved.
L'appareil passera automatiquement maintenir le niveau de confort désiré et arrêter lorsque le
niveau a été atteint.
El aparato mantendrá automáticamente el nivel de confort deseado y se cerrará cuando el nivel
se ha logrado.
** The appliance will run continuously until switched to OFF or AUTOMATIC mode.
L'appareil fonctionne de façon continue jusqu'à ce que passe en mode OFF ou AUTOMATIQUE.
El aparato funciona continuamente hasta que cambia al modo OFF o AUTOMÁTICO.
2
1
4
3
5
6
7
8
9
10
LO
OFF
HI