7083-171B • July 23, 2013 (877) 427- 3316
10
LED
Color
Number of
Flashes between
pauses
Description
Notes
Green
Steady ON while
priming feed tube
(max time 2 min
-
utes)
Feed Motor is running continuously.
(This primes the feed tube).
When priming the feed system and filling
the firepot,
DO NOT OVERFILL FIREPOT
FOR IGNITION
.
The unit will automatically
go into start up following the prime function.
Green
Steady ON while
burning
Room temperature is close to set
point and burning on lowest burnt
rate.
Green
1x
Unit is off and ready.
To start appliance, follow start up sequence.
Green
3x
Appliance is in the start up/ignition
sequence or in shutdown.
During shut down, the blowers will shut off
when the exhaust temperature has cooled.
Green
Varies
When in the automatic mode, the
number of flashes between pauses
indicates the burn rate (1 for low up to
5 for high).
Adjust the dial control to change the desired
room temperature.
Amber
Steady ON
Appliance is set and running at either
the minimum or maximum power
levels.
The unit will shut off only when the hopper
runs out of fuel, the user changes the
dial control to a different state, or the unit
senses an error.
Red
1x
Empty Hopper Alarm
This alarm is caused by the fire going out
from lack of fuel. See troubleshooting sec
-
tion for more information.
Red
2x
Exhaust Probe Alarm
Failed component error. See troubleshoot
-
ing section for more information.
Red
3x
Ambient Probe Alarm
Failed component error. See troubleshoot
-
ing section for more information.
Red
4x
Missed Ignition
There are a total of 2 tries per ignition
sequence. If after 2 tries there is no rise in
exhaust temperature this error will occur.
See the troubleshooting section for addi
-
tional information and correction.
Red
8x
Exhaust Gas Over Temperature Alarm The exhaust temperature exceed the allow
-
able limit. See the troubleshooting section
for more information and correction.
I. LED Color Coding Chart and Explanation
WARNING
Fire Risk
Do NOT operate appliance:
• With appliance door open.
• Firepot floor open.
Do NOT store fuel:
• Closer than required clearances to com
-
bustibles to appliance
• Within space required for loading or ash
removal.