*C: Exception for Horizontal Installations:
CANADA INSTALLATIONS
: A non combustible floor pro
-
tections extending beneath the flue pipe is
required
with
horizontal venting or under the top vent adapter with verti
-
cal installation.
USA INSTALLATIONS
: A non-combustible floor protection
extending beneath the flue pipe is recommended with hori
-
zontal venting or under the top vent adapter with vertical
installation.
A non combustible floor protector is required.
C. Hearth Pad Requirements (UL and ULC)
Use a non-combustible floor protector, extending beneath
appliance and to the front, sides and rear as indicated.
Measure front distance “M” from the surface of the glass
door.
Hearth Pad Requirements
Inches
K
Sides
2
L*
Back
2
M
Front
6
Hearth Pad Requirements
Millimeters
K
Sides
203
L*
Back
51
M
Front
152
USA Hearth Pad Requirements
Canada Hearth Pad Requirements
WARNING
If the information in these instruc-
tions is not followed exactly, a
fire may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other flam
-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not over fire - If heater or chimney
connector glows, you are over firing. Over
firing will void your warranty.
• Comply with all minimum clearances to
combustibles as specified. Failure to
comply may cause house fire.
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
L*
K
M
K