www.pelprostoves.com
7083-171B • July 23, 2013
7
A. User Dial Control
The appliance has one dial control located on the side of
the unit used for daily operation. There are four primary
settings on this dial.
1) OFF: When the dial indicator is in the off position
the unit will go into a shut down and remain off until the
dial is turned to one of the other three settings. The LED
will flash green once per second when in the off position.
2) LO : When the dial indicator is directed to the LO
setting (small flame on the label) the unit will burn on
low until the hopper runs out of pellets or the dial con
-
trol is turned to a different setting. When in this setting
the LED will be amber in color and continuously on.
When burning in this mode, the unit should be turned
off at least once daily for cleaning. If lower quality fuels
are used, additional daily shut downs may be required
for cleaning.
3) HI : Similar to the LO mode, the unit will run continu
-
ously at the high burn rate until the unit has run out of
fuel or the dial is turned to a different setting. To oper
-
ate in this mode, turn the dial clockwise until it stops.
The dial indicator will point to the large flame. When in
this setting the LED will be amber in color and continu
-
ously on. Follow the daily cleaning recommendations
when operating in this mode. If lower quality fuels are
used, additional daily shut downs may be required for
cleaning.
4) COMFORT LEVEL : To burn in the Comfort Level
mode, turn the dial control clockwise to the desired
comfort level. When operating in the automatic mode,
the unit changes the burn setting based on the differ
-
ence between the room temperature and the desired
set point. In other words, the unit will burn on High if the
difference between the desired and room temperature is
greater than 8 degrees Fahrenheit. As the room heats
up and the gap closes, the unit will automatically reduce
the burn rate. When the room temperature is close to
the set point the light will stop flashing stay solid green.
at this time the stove will be burning on the lowest burn
rate. When the desired temperature is achieved the unit
will shut down. As the room cools, the unit will restart
automatically. When burning in this mode the LED will
be blinking green. The number of green flashes corre
-
sponds to the current setting.
B. Filling the Hopper
Slowly open the hopper lid by lifting the handle. The
medium and large units have a locking latch that will
engage when the hopper lid is fully opened. The hopper lid
for the cabinet will open past ninety degrees and stay open
automatically. Fill the hopper with fuel.
FOR USE WITH
ONLY WOOD PELLET FUEL
. Slowly close the hopper lid.
See figure below for releasing the latch. NOTE: The unit
will not feed with the hopper lid open. If left open, the fire
will go out.
Push Bottom of Latch
Inward to Release
C. Priming the Feed Tube
Only if the hopper is being filled for the first time or the
unit had previously run out of pellets, the feed tube may
need to be primed. To do this, turn the dial control from
the OFF position to the HI position two times. This will run
the feed motor continuously for two minutes without turning
the igniter on. When the auger is running continuously,
the LED will be a continuous green color. The system will
run the auger for 2 minutes. When pellets start to drop into
the firepot, the feed tube is primed; turn the dial control
to the desired position and the stove will begin its ignition
sequence (The green LED will flash rapidly).
CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
PART NAME:
DRAWN BY:
SCALE:
MATERIAL:
SHEET:
PART NUMBER:
REV:
THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING
DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.
ECO #
DATE
BY
REV
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03 (3) PLACE DEC: ± 0.005 ANGLE: ± 2° FRACTION: ± 1/16
OUTSIDE MATERIAL.
NORMAL DIM & INSIDE MATERIAL.
OUTSIDE APEX
INSIDE APEX - DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS
REVISIONS
ITEM
PART NUMBER
PART NAME
QTY
02 RELEASE FOR TOOLING
72901
04/29/13
MCW
LABEL CONTROL PANEL
MCW
1:1
SEE NOTE
1 OF 1
7083-167
02
NOTE:
1. MATERIAL: MYLAR
2. ADHESIVE: 3M #468 PERMANENT ACRYLIC
3. TEMPERATURE RATING: INK @ 325°F
TOOLING
3.75
2.81
4X R0.13
2
1
4
3
5
6
7
8
9
10
LO
OFF
HI
0
-1
-2
-3
-4
+1
+2
+3
+4
ON
AUTO
AL
AR
M
CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
PART NAME:
DRAWN BY:
SCALE:
MATERIAL:
SHEET:
PART NUMBER:
REV:
THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING
DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.
ECO #
DATE
BY
REV
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03 (3) PLACE DEC: ± 0.005 ANGLE: ± 2° FRACTION: ± 1/16
OUTSIDE MATERIAL.
NORMAL DIM & INSIDE MATERIAL.
OUTSIDE APEX
INSIDE APEX - DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS
REVISIONS
ITEM
PART NUMBER
PART NAME
QTY
A RELEASED
72906
06/20/13
MCW
LABEL OPERATION AND MAINTENANCE
MCW
NTS
SEE NOTE
1 OF 1
7083-168
A
NOTE:
1. MATERIAL: NON-ANODIZED ALUMINUM 0.020 THICK
2. BACKGROUND: BLACK
3. COPY: SILVER
4. ADHESIVE: 3M #468 PERMANENT ACRYLIC
5. TEMPERATURE RATING: -50°F TO 350°F
RELEASED
-
----
-----
-
6.75
11.75
4X R0.13
2X
Broken Exhaust Probe
Sonde d'échappement cassé
Sonda de escape roto
1X
Empty Hopper
trémie vide
tolva vacía
OFF
3X
Broken Ambient Probe
Cassé la sonde ambiante
Sonda ambiente roto
4X
Failed Ignition
allumage échoué
de encendido no
OFF
8X
High Exhaust Temperature
Température d'échappement haute
Alta temperatura de escape
Troubleshooting
Dépannage / Solución de problemas
Reset From Error
1. Determine error from above table.
2. Correct error condition. (see Owner’s Manual for additional information.)
3. Turn dial control to OFF position, wait 10 seconds.
4. Follow STARTING instructions.
Réinitialisation des erreurs
1. Déterminer l'erreur de tableau ci-dessus.
2. Condition d'erreur correct. (voir le manuel du propriétaire pour plus
d'informations.)
3. Tourner le cadran de commande en position OFF, attendez 10 secondes.
4. Suivez les instructions de démarrage.
Restablecer de error
1. Determinar el error de la tabla anterior.
2. Condición de error correcto. (consulte el Manual del Propietario para
obtener información adicional.)
3. Gire el dial de control en la posición OFF, espere 10 segundos.
4. Siga las instrucciones de arranque.
Customer Service / Service Clients / Servicio al Cliente
877-427-3316
www.pelprostoves.com
Daily / Quotidien / Todos los días
1 Bag / 1 Sac / 1 Bolsa
Empty Firepot / Creuset Vide / Brasero De Fuego Vacía
Clean Firepot / Clean Creuset / Limpieza Brasero De Fuego
Weekly / Hebdomandair / Semanalmente
5 Bags / 5 Sacs / 5 Bolsas
Clean Holes / Nettoyer Les Trous / Limpie Los Orificios
Remove Ash / Retirez Les Cendres / Quitar Las Cenizas
Monthly / Mensuel / Mensualmente
25 Bags / 25 Sacs / 25 Bolsas
1
2
3
Remove / Supprimer / Quitar
Vacuum / Vide / Vacío
Maintenance / Entretien / Mantenimiento
7083-168
Operation / Opération / Operación
Automatic Mode *
mode Automatique
Modo Automático
Priming Fuel
carburant d'amorçage
cebado de combustible
Minimum / Maximum **
minimale / maximale
mínimo / máximo
Starting
1. Turn dial control to OFF position.
2. Fill hopper with pellets.
3. Turn dial control to desired setting.
Départ
1. Tourner le cadran de commande en
position OFF.
2. Remplir la trémie avec des granulés.
3. Tourner le cadran de commande au réglage
désiré.
A partir
1. Gire el dial de control en la posición OFF.
2. Llene la tolva con perdigones.
3. Gire el dial de control hasta la posición deseada.
Stopping
1. Turn dial control to OFF position.
2. Allow unit to cool before performing any maintenance.
Arrêt
1. Tourner le cadran de commande en position OFF.
2. Laissez refroidir avant d'effectuer toute opération de maintenance.
Parada
1. Gire el dial de control en la posición OFF.
2. Deje enfriar la unidad antes de realizar cualquier trabajo de mantenimiento.
* The appliance will automatically maintain the desired comfort level and shut down when level
has been achieved.
L'appareil passera automatiquement maintenir le niveau de confort désiré et arrêter lorsque le
niveau a été atteint.
El aparato mantendrá automáticamente el nivel de confort deseado y se cerrará cuando el nivel
se ha logrado.
** The appliance will run continuously until switched to OFF or AUTOMATIC mode.
L'appareil fonctionne de façon continue jusqu'à ce que passe en mode OFF ou AUTOMATIQUE.
El aparato funciona continuamente hasta que cambia al modo OFF o AUTOMÁTICO.
2
1
4
3
5
6
7
8
9
10
LO
OFF
HI
About 65 •F
About 82 •F
3
General Operating Information