We strongly recommend a minimum of 60 inches
(1.5m) vertical, however above the eave is pre-
ferred.
Both installations are approved for mobile home instal
-
lations. Must use 3 or 4 inch (76 to 102mm) “L” or “PL”
Listed pellet venting or Listed double wall pipe and autho
-
rized Outside Air Kit in mobile homes. Single wall pipe is
approved for residential installations only.
Air Clearance to Pipe
:
This appliance was tested with standard 3 inch (76mm)
Listed pellet vent.
Pellet pipe manufacturers Listed reduced clearance pipe
may be use for reduce clearance from 3 inch (76mm) air
clearance to no less than 1 inch (25mm) air clearance to
combustibles for approved Listed pellet pipe.
Follow pipe manufactures listed air clearances to com-
bustibles and installation instructions for all reduced
air clearances installations.
C.
Vertical into Existing Class A Chimney
A.
Vertical - Interior - Typical Installation
PREFERRED METHOD #1
B.
Through The Wall & Vertical - External -
Horizontal
PREFERRED METHOD #2
Non-combustible Hearth Pad
Clean-out Cover
Tee
Wall Thimble
Support
Bracket
Every 60 in.
(1.5 m)
12 in.
(305mm)
Minimum
Rain Cap
Flashing
2 in. (50.8 mm) Minimum
6 in. (152 mm)
Minimum
Firestop
Flashing
Rain Cap
Non-combustible Hearth Pad
Follow vent manufacturer’s
clearances for reduced clearances
12 in. (305mm) Minimum
Ceiling Support
6 in. (152mm) Flue
Connector
6 in. (152mm) Class A
Chimney Connector
Adapter
6 in.
(152mm)
Min.
10 in. (254mm) Min.
Clean-out T
6 in.
(152mm)
Min.
10 in. (254mm) Min.
Clean-out T
Firestop
Flashing
Rain Cap
Non-combustible Hearth Pad
12 in. (305mm) Minimum
Ceiling Support
9
Venting Systems