7083-171B • July 23, 2013 (877) 427- 3316
28
Fire Risk
Inspection of Chimney:
• Masonry chimney must be in good condition.
• Meets minimum standard of NFPA 211
• Factory-built chimney must be minimum 6 inch
(152mm) UL103 HT.
WARNING
E.
Alternate Masonry
D.
Masonry
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer
to the owner’s information manual provided with this appli
-
ance. For assistance or additional information consult a
qualified installer, service agency or your dealer.
WARNING
Non-combustible
Hearth Pad
Airtight Clean-out Door
Sheathing
2 in. (50.8mm) Minimum
Flashing
1 in. (25mm) Clearance
1 in. (25mm)
Clearance with Firestop
6 in.
(152mm)
Minimum
Fireclay Flue Liner
with Airspace
Concrete
Cap
Airtight
Clean-Out Door
Clean-Out
Sheathing
3 in. (76mm) Minimum
1 in. (25mm) Clearance
Flashing
Fireclay flue
Liner with Airspace
Concrete Cap
1 in. (25mm) Clearance
with Firestop
6 in. (152mm)
Minimum
Non-combustible Hearth Pad