background image

1

Quadra-Fire  •  TOPAZ-MBK-IPI, TOPAZD-PMH-IPI, TOPAZD-MBK-IPI, TOPAZD-CSB-IPI Owner’s Manual  •  2341-981_R4 •  10/15

Models:

TOPAZ-MBK-IPI

TOPAZD-PMH-IPI 

TOPAZD-MBK-IPI

TOPAZD-CSB-IPI

Owner’s Manual

Care and Operation

NOTICE: DO NOT

 discard this manual!

This appliance may be installed as an OEM installation 

in manufactured home (USA only) or mobile home and 

must be installed in accordance with the manufacturer’s 

instructions and the manufactured home construction 

and safety standard, 

Title 24 CFR, Part 3280 

or 

Standard 

for Installation in Mobile Homes, CAN/CSA Z240MH, in 

Canada.
This appliance is only for use with the type(s) of gas 

indicated on the rating plate. 

In the Commonwealth of Massachusetts installation must be 

performed by a licensed plumber or gas fitter.

See Table of Contents for location of additional Commonwealth 

of Massachusetts requirements.

R

INSTALLER: Leave this manual with party responsible for use and operation.

OWNER: Retain this manual for future reference.

Contact your dealer with questions regarding installation, operation or service.

DO NOT

  store  or  use  gasoline  or  other  flammable 

vapors and liquids in the vicinity of this or any other 

appliance.

-  What to do if you smell gas   

• 

DO NOT

 try to light any appliance.

• 

DO NOT

 touch any electrical switch; do not use any 

phone in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

•  If  you  cannot  reach  your  gas  supplier,  call  the  fire 

department.

-  Installation and service must be performed by a qualified 

installer, service agency, or the gas supplier.

WARNING: If the information in these 

instructions is not followed exactly, a fire or 

explosion may result causing property damage, 

personal injury, or death.

HOT GLASS WILL CAUSE 

BURNS.

DO NOT TOUCH GLASS 

UNTIL COOLED.

NEVER ALLOW CHILDREN 

TO TOUCH GLASS.

A barrier designed to reduce the risk of burns 

from the hot viewing glass is provided with 

this appliance and shall be installed for the 

protection of the children and other at-risk 

individuals.

!

DANGER

Cabinet Style

Solitaire

Summary of Contents for TOPAZ-MBK-IPI

Page 1: ...tion OWNER Retain this manual for future reference Contact your dealer with questions regarding installation operation or service DO NOT store or use gasoline or other flammable vapors and liquids in...

Page 2: ...un combustible solide This appliance must be installed in accordance with local codes if any if not follow ANSI Z223 1 in the USA or CAN CGA B149 installation codes Installer l appareil selon les code...

Page 3: ...nce Certification 6 B Glass Specifications Ceramic 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Befo...

Page 4: ...y coverage begins on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the prod...

Page 5: ...FIED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior su...

Page 6: ...imary heat in residential heating calculations 2 Product Specific Information B Glass Specifications Ceramic This appliance is equipped with 5 mm ceramic glass Replace glass only with 5 mm ceramic gla...

Page 7: ...rom hot surfaces Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children Never leave children alone near a hot stove whether...

Page 8: ...in place WARNING Risk of Fire or Asphyxiation DO NOT operate stove with fixed glass assembly removed Figure 3 2 General Operating Parts GLASS ASSEMBLY SECTION 4 B FAN KIT SECTION 6 A CLEAR SPACE SECT...

Page 9: ...T operate the appliance with fixed glass assembly removed cracked or broken Replacement of the fixed glass assembly should be done by a licensed or qualified service person For use with natural gas an...

Page 10: ...lation during stove break in Some people may be sensitive to smoke and odors Smoke detectors may activate G Heat Management Heat Output This model has a variable burn rate which is controlled by the H...

Page 11: ...module damage will occur Figure 3 6 A complete wiring diagram is included in the Electrical section of the appliance Installation Manual 3 Turn the appliance on according to the instructions below fo...

Page 12: ...ion is primarily used for initial installation or power outage operation with battery backup REMOTE Position Appliance will initiate commands from an optional wired wall switch and or the wireless rem...

Page 13: ...ss Inspection Annually Qualified Service Technician Log Inspection Annually Firebox Inspection Annually Control Compartment firebox Top Annually Burner Ignition Operation Annually When properly mainta...

Page 14: ...te control operation instructions for proper calibration and setup procedure Place batteries as needed in remote transmitters and battery powered receivers Place remote control out of reach of childre...

Page 15: ...caution when cleaning these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Figure 4 3 IPI Pilot F...

Page 16: ...ing of the paint and the burning off of any oils remaining from manufacturing If appliance has not been used for some time dust can build up and cause an odor Film on the glass This is a normal result...

Page 17: ...le Check voltage of transformer at connection to module Acceptable read ings of a good transformer are between 6 4 and 6 6 volts DC Bat tery power supply voltage must be at least 4 volts If less than...

Page 18: ...sensing rod to white sensor wire Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod Verify continuity with a multi meter with ohms...

Page 19: ...ard and will void the warranty Remote Controls Switches After a qualified service technician has installed the remote control follow the instructions supplied with the control installed to operate you...

Page 20: ...Parts Service Parts Topaz Beginning Manufacturing Date July 2014 Ending Manufacturing Date Active R TOPAZ IPI Part number list on following page Log Set Assembly Gas Stove DV 09 15 TOPAZ MBK IPI TOPA...

Page 21: ...0040MBK Mahogany 468 0040PMH Sienna Bronze 468 0040CSB 6 Top Black 468 0010MBK Mahogany 468 0010PMH Sienna Bronze 468 0010CSB 7 Shroud Upper Fan Qty 2 req 2340 130 8 Bracket Top Mounting Qty 2 req 23...

Page 22: ...inge Pin 844 5750 Y Magnet Round SRV7000 140 Y Thumbscrew 1 4 20 X 3 4 844 5070 Plate Support 2340 110 15 Screen Assembly Solitare 466 023 Quartet 466 021 16 Refractory Assembly BRICK TOPAZ Y 17 Glass...

Page 23: ...ce parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 22 1 Heat Shield J box 2342 132 22 2 Junction Box 4021 013 Y 22 3 Elbow 3 8 Flare Male 4021 045 22 4 Val...

Page 24: ...r distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 26 1 Starting Collar 2189 002 26 2 Gasket Adaptor 460 0610 26 3 Flue Assembly 2340 025 26 4 Relief Door Guide 2340 133 26 5 Relief...

Page 25: ...0A Y Temp Sensor Limit w Bracket 107 531A Y Firescreen Quartet Front Only 844 9360 Leveling Assembly 7000 000 Mineral Wool 050 721 Ori ce NG 32 Top Vent 582 832 Y Ori ce LP 50 Top Vent 582 850 Y Ori c...

Page 26: ...________________________________________________________________ ________________________________________________________________________________ ______________________________________________________...