PV1000agri pellet burner
p
32/ 50
Operation and maintenance
Statuses and parameters
DK9401A1
www.pelltech.eu
Igniting
In ignition cycle the igniter is heated up and fan blows hot air thru pellets in burning chamber.
Hot air ignites pellets. Igniter is working periodically at ignition time to avoid overheating.
Igniter is preheated already in the end of loading cycle. When internal auger has made 10
rotations (full load rotations* - 12) the igniter is turned on for preheating. If the igniter has been
turned on more than 1 minute at loading time, the igniter is turned off.
Table 7 Ignition parameters
Par
Nr.
Parameter name
Default
value
Unit
Comment
Par 24 Fan @ignition
25
rps Primary fan speed at ignition
-
Max ignition time
255
sek Maximum ignition time
-
First loading time
after manual start
20
min Maximum loading time after manual start.
-
Auger start
3
sec Auger Start delay if no fuel in burner
-
Auger stop
3
sec Auger Stop delay if fuel in burner
-
Feeder start
1
sec Feeder Start delay if fuel in burner
-
Feeder stop
4
rot Feeder rotations made without fuel level before
stopped
Pre-burn
The purpose of pre-burn status is to get correct burning and flame after ignition. There is minimum fuel
amount added periodically at pre-burn time. Fans are working with same speed as at ignition.
Table 8 Pre-burn parameters
Par
Nr.
Parameter name
Default
value
Unit
Comment
Par 8
Fan@ignition
20
rps Primary fan speed at ignition and preburn
Par 39 Fan 2 min
7
rps Secondary fan minimum speed. Used at
“Ignition”, “Preburn”, “Heat up”, “Hold flame”
and “End blow” time.
Par 41 Preburn time
25
s
Delay between pellet feedings at Preburn
Par 42 Preburn cycles
6
x
Number of pellet feeding cycles at Preburn
-
Preburn feed
1/2
rot Feeder turns at each feeding
Heat up
Summary of Contents for PV1000agri
Page 1: ...PV1000agri pellet burner User manual POOLELI DRAFT DK9401A1 ...
Page 24: ...PV1000agri pellet burner p 23 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Page 25: ...PV1000agri pellet burner p 24 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Page 26: ...PV1000agri pellet burner p 25 50 Installation Electrical connections DK9401A1 www pelltech eu ...