Annex B – Burner status change logic
DK9401A1
www.pelltech.eu
8 Annex B – Burner status change logic
Status
Next Status
Change conditions
Waiting
Testing
Signal from boiler thermostat
Testing
Loading
All tests are done successfully
Battery error
Battery voltage is too low
Fan error
Fan does not reach 40* rps at pre-burn
Level error
The level sensor recognizes pellets in the feeder
Loading
Ignition
Loading (22* rot.) made by feeder
No pellets
Maximum loading time (5 or 20 min.**) is reached
Burn end
Flame detected and unknown start conditions
Loading 2
Ignition
Previous state was ignition and rotations (3* rot.) made by feeder
Pre-burn
Previous state was hold flame and rotations (3* rot.) made by feeder
Ignition
Pre-burn
Flame recognized
Loading 2
Max ignition time (255* sec) is reached and load 2 is not done
Ignition error
Max ignition time (255* sec) is reached and load 2 is done
Pre-burn
Burning
Pre-burn cycles (3*x40*sec.) is done and continuous flame is
recognized more than 10 seconds
Loading 2
Pre-burn cycles is done and flame is NOT recognized and load 2 is NOT
done
No flame
Pre-burn cycles is done and flame is NOT recognized and load 2 is done
Burning
Burn end
NO Signal from boiler thermostat (hold flame is NOT allowed)
Hold flame
NO Signal from boiler thermostat (hold flame is allowed)
Burn end
Maximum burning time (4 hours) is reached
Burn end -> End
blow ->Level
error
Fuel level is continuously detected in time of 8 feeder rotations
Burn end -> End
blow ->No
pellets
Fuel level is not detected in 4 min.
No flame
No Flame more than 2 minutes
Hold flame
Loading 2
Signal from boiler thermostat
Burn end
Max keep flame time (1 hour) is reached
Summary of Contents for PV1000agri
Page 1: ...PV1000agri pellet burner User manual POOLELI DRAFT DK9401A1 ...
Page 24: ...PV1000agri pellet burner p 23 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Page 25: ...PV1000agri pellet burner p 24 50 Installation Electrical connections DK9401A1 www pelltech eu ...
Page 26: ...PV1000agri pellet burner p 25 50 Installation Electrical connections DK9401A1 www pelltech eu ...