PV1000a pellet burner
p
54/ 58
DK9401B1 www.pelltech.eu
10 Annex 4 Table of parameters
Firmware version:
bbb: 2.08 22/11/13
PV700a
PV1000a
PAR
PAR Name
Description
Unit
Def
Min
Max
Def
Min
Max
PAR1
FAN@200(250)
Fan speed at 1.power level PV700(PV1000)
rps
28
15
50
24
15
50
PAR2
FAN@300(400)
Fan speed at 2.power level PV700(PV1000)
rps
32
15
50
30
15
50
PAR3
FAN@400(550)
Fan speed at 3.power level PV700(PV1000)
rps
34
15
50
34
15
50
PAR4
FAN@500(700)
Fan speed at 4.power level PV700(PV1000)
rps
37
15
50
38
15
50
PAR5
FAN@600(850)
Fan speed at 5.power level PV700(PV1000)
rps
40
15
50
42
15
50
PAR6
FAN@700(1000)
Fan speed at 6.power level PV700(PV1000)
rps
42
15
50
45
15
55
PAR7
FAN START
Fan speed at TESTING
%
170
80
240
170
80
240
PAR8
FAN@IGNITING
Fan speed at IGNITING and PRE-BURN
rps
20
15
35
20
15
35
PAR9
FAN@END BURN
Fan speed at END BURN
rps
20
10
40
20
10
40
PAR10
FAN@HOLD FLAME Fan speed at HOLD FLAME
rps
10
7
14
10
7
14
PAR11
HOLD FLAME ON
If HOLD FLAME is set to ON in main menu then this
function starts at any case. If HOLD FLAME is set to
AUTO in main menu, then this function starts if time
set with this parameter is shorter than 2 sequential
WAITING times.
min
15
5
30
15
5
30
PAR12
HOLD FLAME OFF
Max time when burner holds flame. HOLD FLAME
function in main menu has to be set to AUTO or ON.
min
60
30
90
60
30
90
PAR13
MIN POWER
Minimum power level up to what burner decreases
output power. Applies if POWER in main menu is in
AUTO status only
kW
200
200
700
250
250
1000
PAR14
MAX POWER
Maximum power level up to what burner decreases
output power. Applies if POWER in main menu is set to
AUTO only
kW
700
200
700
1000
250
1000
PAR15
POWER UP
Timeframe to burner to increase power to one level up
if BURNING state lasts longer than set with this
parameter. Applies if POWER in main menu is set to
AUTO only
min
15
5
120
15
5
120
PAR16
POWER DOWN
Timeframe to burner to decrease power to one level
up if BURNING state lasts longer than set with this
parameter. Applies if POWER in main menu is set to
AUTO only
min
30
15
45
30
15
45
PAR17
UP CYCLE
Pace of increasing targeted power level part-steps
min
2
1
3
2
1
3
PAR18
DOWN CYCLE
Pace of decreasing targeted power level part-steps
min
2
1
3
2
1
3
PAR21
PELLETS NORMAL
Determines how many grams of pellets feeder auger
transports to burning chamber with one full rotation
when PELLET NORM ie normal weight pellets are
selected
g/rot
160
120
250
160
120
250