background image

Set: 1 <0,2> Manufacturer Model 19541MB

S e t : 2 < l > < 3 > CMDRAID1 19541MB

Set: 3 <2> Manufacturer Model  1 9 5 4 1 M B

Press F! to dissolve RAID set

Press F2 to form RAID set

Press <ESC> to exit RAID configuration utility

4. Repeat the process for RAID 1 set (entering 2 for Set 2). The following

screen should appear:

Primary Channel:
Drive Number: 0 Manufacturer Model 19541 MB

Drive Number: 1 Manufacturer Model 19541 MB

Secondary Channel:

Drive Number: 2 Manufacturers Model 19541 MB
Drive Number: 3 Manufacturers Model 1 9541 MB

Set: 1<0,2> Manufacturer Model 19541MB
S e t : 2 < l > < 3 > C M D R A I D l 19541MB
Set: 3 <2> Manufacturer Model 19541MB
Set:4<3> Manufacturer Model 19541MB

Press F1 to dissolve RAID set

Press F2 to form RAID set

Press <ESC> to exit RAID configuration utility

Creating a Mirrored-Striped Set (RAID 0+1 to RAID 10)

1. To create a Mirrored-Striped RAID set (also called RAID 0+1 or RAID 10)

press F2. A Mirrored-Striped set needs all four disk drivers, The following

screen appears:

Primary Channel:

Drive Number: 0 Manufacturer Model 19541 MB

Drive Number: 1 Manufacturer Model 19541 MB

Secondary Channel:

Drive Number: 2 Manufacturers Model 19541 MB
Drive Number: 3 Manufacturers Model 19541 MB

Set: 1<0,2> Manufacturer Model 19541MB

S e t : 2 < l > < 3 > C M D R A I D l 19541MB

Set:3<2> Manufacturer Model 19541MB
Set:4<3> Manufacturer Model  1 9 5 4 1 M B

Summary of Contents for Ultra 133

Page 1: ...PCI Ultra 133 RAID Card User s Manual...

Page 2: ...kage Content P I System Requirement P I Hardware Installation P 2 Software Installation P 2 Appendix P 3 Creating Striped Sets RAID 0 P 3 Creating Mirrored Sets RAID 1 P 5 Deleting RAID Sets P 6 Creat...

Page 3: ...cification revision 1 0 Compliant with Programming Interface for Bus Master IDE Controller revision 1 0 Compliant with ATA ATAPI 6 specifications Compliant with UDMA6 ATA 133 Specification Driver supp...

Page 4: ...RAID Controller should appear in th listing 6 Right click on RAID Controller 7 Select Properties 8 Select Driver tab 9 Select Update Driver 10 Follow directions in Wizard Be sure to select Display a...

Page 5: ...r RAID utility 2 Press F3 3 The following screen will appear Primary Channel Drive Number 0 Manufacturer Model 19541 MB Drive Number 1 Manufacturer Model 19541 MB Secondary Channel Drive Number 2 Manu...

Page 6: ...1 2K 2 4K 3 8K4 16K 5 32K 6 64K 7 128K 8 256K 9 5M Yourselection 6 Choose the chunk size desired for example press 5 for 32K chunk size Once done the following screen appears Enter the total number o...

Page 7: ...a RAID set Drive 1 could be part of Set 1 ifit is part ofa RAID set with Drive 0 Ifnot it will be part ofSet 2 For example if a striped set were created with drives 1 and 2 the sets Would be Set 1 0...

Page 8: ...e Number 3 Manufacturers Model 19541 MB Set 1 0 2 CMD RAIDO 39081MB Set 2 l 3 CMDRAIDl 19541MB Press F1 to dissolve RAID set Press F2 to form RAID set Press ESC to exit RAID configuration utility Note...

Page 9: ...3 CMDRAIDl 19541MB Set 3 2 Manufacturer Model 19541MB Set 4 3 Manufacturer Model 19541MB Press F1 to dissolve RAID set Press F2 to form RAID set Press ESC to exit RAID configuration utility Creating a...

Page 10: ...or equal to the total capacity ofthe destination drives for example choose 0 The following screen appears Enter the second source dive number in RAIDO 1 set 5 For example choose 2 The following scree...

Page 11: ...harmful interference when the equipment is operated in a residential Installation This equipment generates uses and can radiate radio frequency energy and Ifnot installed and used in accordance to th...

Reviews: