PCE Instruments PCE-DDM 10 Manual Download Page 3

Manual 

 

 

Introduction 

Thank you for purchasing PCE-DDM series crane scales from PCE Instruments. 
These crane scales which are made of high-quality materials are perfectly suitable for mobile tension 
measurements, e. g. as carried out by consultants. They have a high measurement capacity but are also 
compactly constructed with a low net weight. 

Safety notes 

2.1 

General 

Please read this manual carefully and completely before you use the device for the first time. The device 
may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no 
warranty of damage or injuries caused by non-observance of the manual.

 

 
- The device may only be used in approved temperature ranges as laid down in the specifications. 
Exposure to extreme temperatures, direct sunlight, extreme atmospheric humidity or wetness (e. g. wet 
hands) must be avoided. 

The case must only be opened by qualified personnel of PCE Instruments.

 

- The instrument should never be placed with the user interface facing an object (e.g. keyboard side on a 
table). 
- You should not make any technical changes to the device. 
- The appliance should only be cleaned with a damp cloth / use only pH-neutral cleaner, no abrasives or 
solvents. 
- If you do not use the device for a longer period of time, remove the batteries. 
- The device may only be used with PCE accessories or equivalent. 
- Do not use the device in potentially explosive atmospheres. 
- Do not weigh more than the maximum capacity. 
- To avoid hazards arising from load lifting, the producer as well as the user have to comply with certain 
duties. The use of the measuring equipment may at no time be hazardous. 
- The person responsible for the measuring equipment as well as the user must observe and fulfill the 
national regulations, e. g. regulations for accident prevention, safety regulations, work protection 
regulations and all other regulations applicable for the use of the measuring equipment. 
- Other directives such as regulations and safety information for the use of the measuring equipment must 
be borne in mind, for example those of the crane producer, of the load suspension device producer and of 
the shackle producer. 
- In this relation, the measurement equipment may only be mounted, put into service, maintained and 
operated by qualified personnel using appropriate protective equipment. 
- The measuring equipment must not be changed and may only be used for intended purposes. 
- The measuring equipment as well as all other equipment (e. g. the crane, the load suspension devices 
etc.) must be maintained, serviced and accordingly recorded regularly. Before each use of this 
equipment, you should at least visually inspect it. In case the equipment is incomplete or damaged (e. g. 
cracks, deformations, split-offs) the equipment must be taken out of service. It is urgently necessary to 
get advice from your company’s responsible safety representative regarding this matter. 
- Repairs may only be carried out by qualified personnel and only quality-tested spare parts must be 
used. All repairs, maintenance work and spare parts must be documented by the service partner. 
- The manual as well as the safety notes should always be with the measuring equipment. 
- The measuring equipment is 

not ex-protected

 and may not be used in potentially explosive 

atmospheres. The environmental conditions such as the temperature ranges can be seen from the 
manual and must be adhered to. Aggressive or corrosive areas of application must be avoided. When the 
temperature fluctuates severely, an acclimatization period must be included. 
- The measuring equipment is only approved for lifting and weighing freely-moveable loads. Torsion 
(torsional stress) of the load is not allowed. Carrying persons, pulling, tearing, towing etc. of loads is 
prohibited. 
- The permissible nominal load [MAX] of the measuring equipment and other equipment in use (e. g. 
crane, lifting fixation device etc.) may under no circumstances be exceeded. 
- When you use the equipment, you must always observe the possible danger zone. Do not enter the 
danger zone during use. This does not only include the area directly under the load but also the areas 
which can be dangerous due to e. g. swinging ropes or other load suspension devices. 

Summary of Contents for PCE-DDM 10

Page 1: ...nts UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From Outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instr...

Page 2: ...ide 9 5 3 1 ON OFF 9 5 3 2 Zero 9 5 3 3 TARE 9 5 3 4 PEAK HOLD 9 5 3 5 Data memory 9 5 3 6 Data search 9 5 3 7 Delete memory 10 5 3 8 Battery voltage 10 5 3 9 To change the unit 10 5 3 10 To return to...

Page 3: ...of the measuring equipment must be borne in mind for example those of the crane producer of the load suspension device producer and of the shackle producer In this relation the measurement equipment m...

Page 4: ...ar of the attachment parts Control all dimensions Consider all possible deformations and damage Make sure that all parts work properly Every 12 months or 50000 measurements whatever happens first Insp...

Page 5: ...ies operation time approx 50 h battery life 40 hours model range resolution minimum load weight with shackle PCE DDM 3 3000 kg 30 kN 1 kg 10 N 10 kg 2 kg 5 kg PCE DDM 5 5000 kg 50 kN 2 kg 20 N 40 kg 3...

Page 6: ...mm B mm C mm D mm mm H mm Material PCE DDM 3 260 123 37 195 51 365 aluminium PCE DDM 5 285 123 57 210 58 405 aluminium PCE DDM 10 320 120 57 230 92 535 steel PCE DDM 20 375 128 74 260 127 660 steel PC...

Page 7: ...ta memory f STB stable condition g kN kilonewton N newton in taring mode the N flashes h t tonne i lb lbs k kg kilogrammes 5 1 2 Keypad a ON OFF 1 Press the ON OFF key to switch the device on 2 When t...

Page 8: ...to measurement mode Press MODE 4 times The display will show Unit Then press ENTER to get to the mode in which you can select the unit Press Zero to select the unit and Mode to return to measurement...

Page 9: ...switches off automatically after 60 minutes 5 3 2 Zero OPERATION DISPLAY When the device is switched on it normally displays In case it shows small numbers press this key 1 Press ZERO 2 Press ZERO 5 3...

Page 10: ...calibration You can use the hand held device to select parameter settings or calibration 5 4 1 Key functions Key Function Tare to change numbers ZERO to increase values MODE to save and exit ENTER to...

Page 11: ...rated it will display the calibrated value Press Zero to select Select the unit Un 0 kg Un 1 lb Un 2 N Un 3 KN Un 4 t Normally select Un 0 Press Enter to confirm If the device is new it will display O...

Page 12: ...after attaching the tare weight You can also attach the tare weight before switching the device on Press MODE 8 times The display will show CLIBr Press ENTER and hold it for 3 seconds to confirm the c...

Page 13: ...attached before STB light flashes 5 6 Troubleshooting problem possible reason solution no display batteries defective replace key defective call support ON OFF key has not been pressed properly press...

Page 14: ...a recycling company which disposes of the devices in line with law If you have any questions please contact PCE Instruments 7 Contact If you have any questions about our range of products or measurin...