Note:
If the Difference mode is adjusted, the controller uses the S5 sensor
input for measuring the store sensor temperature. The 3-port valve has
to be mounted such that it is normally open towards the lower store
zone or the cooler store respectively. In order to protect the stratifi ca-
tion in the upper store zone or the warmer store respectively, the store
sensor must be mounted in the upper store zone or the warmer store
respectively.
3.6
Basic settings
Basic settings
Adjustment
channel
Description
Adjustment range / selection
Factory
setting
Language
Selection of the menu language
Deutsch, English, Francais,
Espanol, Italiano, Nederlands,
Português
Deutsch
Auto DST Automatic daylight saving time adjust-
ment
Yes, No
Yes
Date
Adjustment of the current date
01.01.2001 … 31.12.2099
01.01.2010
Time
Adjustment of the current time
00:00 … 23:59
-
T-display
standby
Display illumination time
10 … 300 s
30 s
Factory
setting
back to factory settings
Yes, No
No
back
In the Basic settings menu, all basic parameters for the controller can be adjusted.
Normally, these settings have been made during commissioning. They can be subse-
quently changed in this menu.
3.7
SD card
The controller is equipped with an SD card slot for SD memory cards.
With an SD card, the following functions can be carried out:
• Logging measurement and balance values in the csv format. After the transfer to
a computer, the values can be opened and visualised, e. g. in a spreadsheet.
• Store adjustments and parameterisations on the SD card and, if necessary,
retrieve them from there.
• Running fi rmware updates on the controller.
Firmware updates
When an SD card with a fi rmware update is inserted, the enquiry Update? is indi-
cated on the display. The setting can be changed between Yes and No by pressing
buttons
❷
and
❹
.
Î
To run the update, select Yes and confi rm by pressing button
➄
.
The update is run automatically. The indication Please wait and a progress bar
appear on the display. When the update has been completed, the controller will
automatically reboot and run a short initialisation phase.
Î
To skip the update, select No.
The controller commences normal operation.
Note:
The controller will only recognise a fi rmware update fi le if it is stored in
a folder named FC413 on the fi rst level of the SD card.
Î
Create a folder named FC413 on the SD card and extract the down-
loaded ZIP fi le into this folder.
Starting the logging
Î
Insert the SD card into the slot
Î
Adjust the desired logging type and interval
Logging will start immediately.