background image

Management

59

SmartNode 4900 User Manual 

B • Specifications

802.1p VLAN tagging

IPSEC AH & ESP Modes

Manual Key; IKE optional

AES/DES/3DES Encryption

Management

Industry standard CLI with local console (RJ-45, RS-232) and remote Telnet access

TFTP configuration & firmware loading

SNMP v1 agent (MIB II and private MIB)

Built-in diagnostic tools (trace, debug)

Operating environment

Temperature

Operating range: 32–104°F (0–40°C)

 

Internal temperature: Available in real-time on the IpChannel Bank web pages

Humidity

5 to 90% relative humidity (RH), non-condensing

Altitude

Maximum operating altitude: 15,000 feet (4,752 meters)

System 

The processor is a Motorola MPC875 series 32-bit PowerPC core, 133 MHz

8 MB Flash

32 MB SDRAM

Dimensions 

1.75 inches (4.44 cm) height, standard 19-inch (48.26 cm) width, 12 inches (30.48 cm) depth

Weight and power dissipation

See 

table 12

.

Table 12. SmartNode weight and maximum power specifications

SmartNode model

Weight

Maximum power dissipation

IpChannel Bank 4912

9.1 lb (4.1 kg)

25W

IpChannel Bank 4916

9.1 lb (4.1 kg)

30W

IpChannel Bank 4924

9.1 lb (4.1 kg)

40W

Summary of Contents for SmartNode 4900

Page 1: ...IpChannel Bank User Manual Sales Office 1 301 975 1000 Technical Support 1 301 975 1007 E mail support patton com WWW www patton com Part Number 07MSN4900 GS Rev H Revised February 8 2012 Start Installation For Quick ...

Page 2: ...nt is furnished under a license and may be used or copied only in accordance with the terms of such license For information about the license see Appendix E End user license agreement on page 70 or go to www patton com Patton Electronics warrants all SmartNode router components to be free from defects and will at our option repair or replace the product should it fail within one year from the firs...

Page 3: ...tion 24 4 Getting started with the SmartNode 4900 Series 36 5 LEDs status and monitoring 46 6 Contacting Patton for assistance 48 A Compliance information 51 B Specifications 55 C Port pin outs 61 D Factory Configuration 68 E End user license agreement 70 F Installation checklist 73 G Accessories 75 ...

Page 4: ...t panel 18 SmartNode 4900 Series rear panels 19 Reset button behavior 20 2 Applications overview 21 Introduction 22 SmartNode 4900 Series applications 22 Multiservice carrier access over leased lines 22 Enterprise FXS concentration and extension over IP and T1 E1 23 Bulk analog line extensions 23 3 Hardware installation 24 Introduction 25 Planning the installation 25 Installation checklist 26 Site...

Page 5: ...7 1 Configure IP address 38 Factory default IP settings 38 Connect to the RS 232 console port 39 Login 40 Changing the WAN IP address 40 2 Connecting the SmartNode to the network 41 3 Loading the configuration optional 41 Bootloader 42 Start Bootloader 42 Start up with factory configuration 43 Load a new application image SmartWare via TFTP 43 Load a new application image SmartWare via the serial ...

Page 6: ...7 FXO ports 57 PPP and Frame Relay support 57 Voice processing signaling dependent 57 Fax and modem support 57 Voice signaling 58 Voice routing session router 58 IP services 58 Management 59 Operating environment 59 Temperature 59 Humidity 59 Altitude 59 System 59 Dimensions 59 Weight and power dissipation 59 Power supply 60 Universal AC version 60 DC version 60 Identification of the SmartNode dev...

Page 7: ...ble of Contents End User License Agreement 71 1 Definitions 71 2 Title 71 3 Term 71 4 Grant of License 71 5 Warranty 71 6 Termination 72 7 Other licenses 72 F Installation checklist 73 Introduction 74 G Accessories 75 Introduction 76 ...

Page 8: ...gh RJ 45 to RJ 45 Ethernet cable diagram 30 9 Cross over RJ 45 to RJ 45 Ethernet cable diagram 30 10 DB 9 to RJ 45 cable diagram 31 11 IEC 320 connector and grounding stud locations 32 12 Grounding stud and power cable retainer clip 33 13 DC connector DC and DC input view 34 14 Connecting the SmartNode to your laptop PC 37 15 Connecting the SmartNode to the network 37 16 Loading the configuration ...

Page 9: ...ss and network mask configuration 38 10 SmartNode LED Indicators 47 11 Rear panel expansion port LEDs 47 12 SmartNode weight and maximum power specifications 59 13 SmartNode Models and their Unique sysObjectID 60 14 V 35 serial port signals DB 25 connector 63 15 X 21 serial port signals DB 15 connector 63 16 Band marked color codes for the 64 pin RJ 21X connector 64 17 Band marked color codes for ...

Page 10: ...eries on page 36 describes getting started with the SmartNode IpChannel Bank Chapter 5 LEDs status and monitoring on page 46 contains definitions for the LED status indicators Chapter 6 Contacting Patton for assistance on page 48 contains information on contacting Patton tech nical support for assistance Appendix A Compliance information on page 51 contains compliance information for the SmartNode...

Page 11: ... heading calls attention to important information The alert symbol and CAUTION heading indicate a potential hazard Strictly follow the instructions to avoid property damage The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard Strictly follow the instructions to avoid property damage caused by electric shock The alert symbol and WARNING heading indicate a potential...

Page 12: ...ts all applicable standards for the coun try in which it is to be installed and that it is connected to a wall outlet which has earth ground Hazardous network voltages are present in WAN ports regardless of whether power to the SmartNode is ON or OFF To avoid electric shock use caution when near WAN ports When detaching the cables detach the end away from the SmartNode first Because telephone line...

Page 13: ... moist anti static cloth Place the unit on a flat surface and ensure free air circulation Avoid exposing the unit to direct sunlight and other heat sources Protect the unit from moisture vapors and corrosive liquids Always follow ESD prevention procedures when removing and replacing cards Wear an ESD preventive wrist strap ensuring that it makes good skin contact Connect the clip to an unpainted s...

Page 14: ...type Parts of commands which are related to elements already named by the user are in boldface italic font Italicized Futura type Variables for which you supply values are in italic font Futura type Indicates the names of fields or windows Garamond bold type Indicates the names of command buttons that execute an action Angle brackets indicate function and keyboard keys such as SHIFT CTRL C and so ...

Page 15: ...General information Chapter contents SmartNode 4900 Series overview 16 SmartNode 4900 Series detailed description 17 SmartNode 4900 Series front panel 18 SmartNode 4900 Series rear panels 19 Reset button behavior 20 ...

Page 16: ...ase T Ethernet ports from 12 to 32 FXS ports and an integrated optional V 35 or X 21 serial WAN port This provides voice over IP VoIP and Internet telephony integrated with routed serial WAN access The SN4900 IpChannel Bank supports Frame Relay and PPP networking with VPN and firewall functions and provides extensive quality of service QoS features for best possible voice quality over any broadban...

Page 17: ...35 or X 21 serial WAN port Ethernet port ETH0 1 is commonly used for the LAN connection ETH0 0 can be used for WAN access or as a second LAN connection The customer s application will determine whether the serial expansion port or ETH0 0 is used for WAN connectivity The following base model numbers are available SN4912 JSx RUI 12 FXS ports SN4916 JSx RUI 16 FXS ports SN4924 JSx RUI 24 FXS ports SN...

Page 18: ...olid green Blinking green Ethernet Port 0 is up Indicates activity ETH1 Solid green Blinking green Ethernet Port 1 is up Indicates activity 20 Green 20 of the voice ports are active 40 Green 40 of the voice ports are active 60 Green 60 of the voice ports are active 80 Green 80 of the voice ports are active 100 Green 100 of the voice ports are active UNI T EQU IPP ED WIT H DUA L SUP PLI ES DIS CO N...

Page 19: ...Console Reset Expansion ETH 0 1 Status Activity 36 72V 1 6 AMP Telco Ports 36 72V 1 6 AMP ETH 0 0 NIC ADDRESS 00 A0 BA 00 04 10 Console Telco Ports Reset Expansion ETH 0 1 Status Activity 36 72V 1 6 AMP 100 240V 50 60 Hz 1 AMP 100 240V 50 60 Hz 1 AMP ETH 0 0 NIC ADDRESS 00 A0 BA 00 04 10 Console Telco Ports Reset ETH 0 1 100 240V 50 60 Hz 1 AMP 100 240V 50 60 Hz 1 AMP ETH 0 0 NIC ADDRESS 00 A0 BA ...

Page 20: ...k connects the unit to an Ethernet LAN Expansion V 35 serial port DB 25 connector data rates up to 2 Mbps Frame Relay or PPP protocols Status and Activity LED indicators configured as DTE X 21 serial port DB 15 connector data rates up to 2 Mbps Frame Relay or PPP protocols Status and Activity LED indicators configured as DTE Console RS 232 control port Used for service and maintenance the Console ...

Page 21: ...s overview Chapter contents Introduction 22 SmartNode 4900 Series applications 22 Multiservice carrier access over leased lines 22 Enterprise FXS concentration and extension over IP and T1 E1 23 Bulk analog line extensions 23 ...

Page 22: ... port The two Ethernet ports provide full featured IP routing plus Ethernet and IP layer QoS services The sync serial port provides WAN access for integrated voice and data via a leased line connection to the network Voice prioritization and traffic management avoid network congestion and provide optimal voice quality The following sections show two typical converged voice and data applications Mu...

Page 23: ...erprise network administrators with a simple and cost effective option to provide a large number of FXS ports in a remote location see figure 5 Figure 5 Enterprise FXS concentration and extension over IP and T1 E1 Bulk analog line extensions The SN4900 FXO and FXS models used in combination enable enterprises to extend up to 32 analog phone lines over any IP link be it the public Internet a leased...

Page 24: ...nel Bank 28 IpChannel Bank chassis installation 28 Connecting cables 29 Connecting the FXS ports 29 Connecting the FXO ports 29 Connecting the Ethernet ports 30 Connecting the 10 100Base T Ethernet ports to an Ethernet switch or hub 30 Connecting a 10 100Base T Ethernet port to an Ethernet capable workstation 31 Connecting the EIA 561 RS 232 configuration port DCE configured 31 Connecting the seri...

Page 25: ...p the device See table 5 for an example of installment checklist that may be necessary for a smoother installation Completing the pre installation checks enables you to install and set up your IpChannel Bank within an existing network infrastructure with confidence Before installing the IpChannel Bank device the following tasks should be completed Prepare an installation checklist using the list p...

Page 26: ...ecorded in site log Environmental specifications verified Site power voltages verified Installation site pre power check completed Required tools available Additional equipment available All printed documents available SmartWare release build number verified Rack desktop or wall mounting of chassis completed Initial electrical connections established ASCII terminal attached to console port Cable l...

Page 27: ...atekeeper if used IP addresses of central PSTN Gateway for H 323 based calls IP addresses of central TFTP Server used for configuration upload and download Configuration tools You will need a PC or equivalent with a VT 100 emulation program e g HyperTerminal to configure the software on your SmartNode 4900 AC Power Mains If you suspect that your AC power is not reliable for example if room lights ...

Page 28: ...e container contents Report any equipment damage to the shipping carrier immediately for claim purposes Save all packing mate rial in case you need to return an item to the factory for servicing The IpChannel Bank comes with the following items Model SN4900 Series IpChannel Bank Quick Start Guide Model SN4900 Series IpChannel Bank An RJ 45 to RJ 45 cable for use with the console and Ethernet ports...

Page 29: ...he cable into the 64 pin or 50 pin RJ 21X receptacle on the IpChannel Bank The pin count will depend on the IpChannel Bank that you ordered 2 The other end of the cable has 25 non terminated twisted pairs for connection to punch down blocks Select the twisted pairs which will be used for 3 Select and attach the appropriate twisted pair from each FXO device on punch down blocks for connec tion to t...

Page 30: ...ernet switch or hub The 10 100Base T Ethernet port is designed to connect to an Ethernet switch or hub with a straight through or cross over Ethernet cable The Ethernet RJ 45 pin and signal definitions for the SN4900 or for a NIC card in a workstation PC are shown in figure 7 Connect a CAT 5 cable one wired as shown in figure 8 or figure 9 between the SN4900 and the hub switch Figure 7 Model SN490...

Page 31: ...ial ports see table 8 via a cable terminated at the SmartNode 4900 The V 35 connector is a DB 25 female and the X 21 uses a DB 15 female The sync serial ports are configured as DTE Table 8 Serial port pin outs V 35 Interface DB 25 X 21 interface DB 15 Pin Description Pin Description 1 Frame Ground 1 Signal Ground 2 TD a to DCE 2 Transmit to DCE 3 RD a from DCE 3 Control to DCE 4 RTS to DCE 4 Recei...

Page 32: ...ecting to a DC power source see Installing the power cables DC units on page 34 Grounding the Model SN4900 AC and DC units Do the following 1 Assemble a ground wire using 10 AWG wire with green colored insulation and two ring terminals Make the wire long enough to reach one of the following earth ground sources The building ground rod generally located at the site s main service entrance A sprinkl...

Page 33: ...artNode router is equipped with dual power supplies Disconnect both power supply cords before servicing For systems without a power switch line voltages are present within the power supply when the power cords are connected The mains outlet that is utilized to power the SmartNode router shall be within 10 feet 3 meters of the device shall be easily accessible and protected by a circuit breaker The...

Page 34: ...crew down terminal block see figure 13 Figure 13 DC connector DC and DC input view 1 Connect the earth ground of the DC source to the grounding stud on the DACS as described in the previ ous section entitled Grounding the Model SN4900 AC and DC units 2 Strip back the insulation on each of the wires approximately 1 4 inch Mains Voltage Do not open the case when either power cord is attached The Sma...

Page 35: ...there are no exposed wires 4 Repeat steps 1 through 3 to install the remaining DC power connection 5 Connect the equipment to a 36 72 VDC 2 5A supply source that is electrically isolated from the AC source The 36 72 VDC source is to be reliably connected to earth ground 6 Verify that the green POWER LED is lit Hardware installation is complete Refer to chapter 4 Getting started with the SmartNode ...

Page 36: ...the RS 232 console port 39 Login 40 Changing the WAN IP address 40 2 Connecting the SmartNode to the network 41 3 Loading the configuration optional 41 Bootloader 42 Start Bootloader 42 Start up with factory configuration 43 Load a new application image SmartWare via TFTP 43 Load a new application image SmartWare via the serial link 45 Additional information 45 ...

Page 37: ...the SmartNode to the network 10 0 24 0V 5 0 60 Hz 1 AM P UNI T EQU IPP ED WIT H DUA L SUP PLI ES DIS CO NNE CT BOT H SUP PLI ES BEF OR E SER VIC ING UNI T EQU IPP ED WIT H DUA L SUP PLI ES DIS CO NNE CT BOT H SUP PLI ES BEF OR E SER VIC ING 10 0 24 0V 5 0 60 Hz 1 AM P ET H 0 0 NI C AD DR ES S 00 A 0 BA 00 04 10 Co ns ole Te lco Po rts 50 1 Re se t Ex pa ns ion ET H 0 1 St atus Ac tiv ity Console p...

Page 38: ...ting the SmartNode to the net work on page 41 Otherwise refer to the following sections to change the addresses and network masks Table 9 Factory default IP address and network mask configuration IP Address Network Mask WAN interface Ethernet 0 ETH 0 0 DHCP DHCP LAN interface Ethernet 1 ETH 0 1 192 168 1 1 255 255 255 0 24 DHCP IP address range 192 168 1 10 192 168 1 19 255 255 255 0 24 10 0 24 0V...

Page 39: ...hat supports the serial interface e g HyperTerm Figure 17 Connecting to the RS 232 Console port Terminal emulation program settings Asynchronous 9600 bps No parity 8 bit 1 stop bit No flow control 10 0 24 0V 5 0 60 Hz 1 AM P UNI T EQU IPP ED WIT H DUA L SUP PLI ES DIS CO NNE CT BOT H SUP PLI ES BEF OR E SER VIC ING UNI T EQU IPP ED WIT H DUA L SUP PLI ES DIS CO NNE CT BOT H SUP PLI ES BEF OR E SER...

Page 40: ... ip router 192 168 1 1 ctx ip router Now you can set your IP address and network mask for the interface ETH 0 0 WAN Within this example a network 172 16 1 0 24 address is assumed The IP address in this example is set to 172 16 1 99 you should set this the IP address given to you by your network provider 172 16 1 99 ctx ip router interface eth0 172 16 1 99 if ip eth0 ipaddress 172 16 1 99 255 255 2...

Page 41: ...nd Summary of the SmartNode Series SmartWare Software Configura tion Guide 3 Loading the configuration optional Patton provides a collection of configuration templates on the support page at www patton com smart node one of which may be similar enough to your application that you can use it to speed up configuring the SmartNode Simply download the configuration note that matches your application t...

Page 42: ...fig Press yes to store no to drop changes no Press yes to restart no to cancel yes The system is going down Bootloader The bootloader ensures that basic operations network access and downloads are possible in case of interrupted or corrupted application image downloads It offers console access to the Bootloader and the capability for downloading application images e g SmartWare via the serial link...

Page 43: ...d to receive the new application image mask_len is the length of the network address or the number of 1 s within the subnet mask See Note below 2 optional RedBoot ip_address g gateway Sets the IP address of the default gateway 3 optional RedBoot ping h tftp server_ip_address Tests the connectivity to the TFTP server 4 RedBoot load r v h host b base_address file_name Downloads an application image ...

Page 44: ...SmartWare RedBoot ip l 172 16 40 98 19 RedBoot ip g 172 16 32 1 RedBoot ping h 172 16 32 100 Network PING from 172 16 40 98 to 172 16 32 100 PING received 10 of 10 expected RedBoot load r v h 172 16 32 100 b 0x1800100 Sn4xxx image bin Using default protocol TFTP Raw file loaded 0x01800100 0x0199ca6b 1689964 bytes assumed entry at 0x01800100 RedBoot fis delete n 1 Delete image 1 continue y n y Eras...

Page 45: ...m ymodem b base_address Downloads an application image into the volatile memory RAM from where the SmartNode could directly execute it xmodem or ymodem Specify the protocol to be used X Modem or Y Modem base_address memory location where to store the application image Use the default address 0x1800100 Execute the above RedBoot command first then start the trans fer from the terminal program with t...

Page 46: ...46 Chapter 5 LEDs status and monitoring Chapter contents Status LEDs 47 ...

Page 47: ...es the gateway is registered on a gatekeeper media gateway controller associated to a remote unit or has an active VoIP connection Indicates the unit is attempting or has failed to associate or register ETH 0 0 Solid green Blinking green Ethernet port 0 is up Indicates activity ETH 0 1 Solid green Blinking green Ethernet port 1 is up Indicates activity 20 Call Load Green 20 of the voice ports are ...

Page 48: ...er contents Introduction 49 Contact information 49 Warranty Service and Returned Merchandise Authorizations RMAs 49 Warranty coverage 49 Out of warranty service 50 Returns for credit 50 Return for credit policy 50 RMA numbers 50 Shipping instructions 50 ...

Page 49: ...975 1007 Alternate Patton support for Europe Middle East and Africa EMEA Online support available at www patton inalp com E mail support e mail sent to support patton inalp com will be answered within 1 business day Telephone support standard telephone support is available five days a week from 8 00 am to 5 00 pm CET 0900 to 1800 UTC GMT by calling 41 0 31 985 25 55 Fax 41 0 31 985 25 26 Warranty ...

Page 50: ... be issued upon receipt and inspection of the equipment 30 to 60 days We will add a 20 restocking charge crediting your account with 80 of the purchase price Over 60 days Products will be accepted for repairs only RMA numbers RMA numbers are required for all product returns You can obtain an RMA by doing one of the following Completing a request on the RMA Request page in the Support section at ww...

Page 51: ...nce 52 EMC compliance 52 Safety compliance 52 PSTN Regulatory Compliance 52 Radio and TV interference FCC Part 15 52 CE Declaration of Conformity 52 Authorized European Representative 52 FCC Part 68 ACTA Statement FXO ports 54 Industry Canada Notice FXO Ports 54 ...

Page 52: ...there is no guarantee that inter ference will not occur in a particular installation If the equipment causes interference to radio or television reception which can be determined by disconnecting the cables try to correct the interference by one or more of the following measures moving the computing equipment away from the receiver re orienting the receiving antenna and or plugging the receiving e...

Page 53: ...Authorized European Representative 53 SmartNode 4900 User Manual A Compliance information Watchfield Swindon Wilts SN6 8TD UK ...

Page 54: ... commission public service commission or corporation commission for information Industry Canada Notice FXO Ports This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications This is confirmed by the registration number The abbreviation IC before the registration number signifies that reg istration was performed based on a Declaration of Conformity indicating that...

Page 55: ...me Relay support 56 Voice processing signaling dependent 56 Fax and modem support 56 Voice signaling 57 Voice routing session router 57 IP services 57 Management 58 Operating environment 58 Temperature 58 Humidity 58 Altitude 58 System 58 Dimensions 58 Weight and power dissipation 58 Power supply 59 Universal AC version 59 DC version 59 Identification of the SmartNode devices via SNMP 59 ...

Page 56: ... supporting 100Base TX half full duplex operation 10Base TX half full duplex operation Auto detection and fallback Console port The RS 232 port provides for initial configuration of the Model SN4900 series The RS 232 port supports Asynchronous data rate of 9600 bps 2 bits no parity 1 stop bit no flow control An RJ 45 connector with EIA 561 RS 232 pinouts A management interface such as HyperTermina...

Page 57: ...our an encapsulation method created by the four companies Cisco Northern Telecom StrataCom and DEC which differs from the IETF encapsulation PPP PAP CHAP LCP IPCP Voice processing signaling dependent Voice codecs G 711 A Law Law 64 kbps G 726 ADPCM 40 32 24 16 kpbs G 723 1 5 3 or 6 3 kbps G 729ab 8 kbps Transparent pass through G 168 echo cancellation Up to 32 parallel voice connections DTMF detec...

Page 58: ... H 323 Annex M3 SIP SIPv2 RFC3261 RFC3263 SIP call transfer redirect DTMF relay Voice routing session router Local switching Interface huntgroups Routing Criteria Interface Calling called party number Time of day day of week date Number manipulation functions Replace numbers Add remove digits Multiple remote gateways PLAR IP services IPv4 router RIPv1 v2 RFC 1058 and 2453 Programmable static route...

Page 59: ...ure Available in real time on the IpChannel Bank web pages Humidity 5 to 90 relative humidity RH non condensing Altitude Maximum operating altitude 15 000 feet 4 752 meters System The processor is a Motorola MPC875 series 32 bit PowerPC core 133 MHz 8 MB Flash 32 MB SDRAM Dimensions 1 75 inches 4 44 cm height standard 19 inch 48 26 cm width 12 inches 30 48 cm depth Weight and power dissipation See...

Page 60: ...ification MIB IpChannel Bank 4932 9 1 lb 4 1 kg 50W V 35 or X 21 Serial Card Expansion Port 0 1 lb 45 3 g 1W Table 13 SmartNode Models and their Unique sysObjectID SmartNode Model SysObjectID SN4912 JS iso org dod internet private enterprises patton products sn49xx 2 1 3 6 1 4 1 1768 2 4 7 2 SN4916 JS iso org dod internet private enterprises patton products sn49xx 3 1 3 6 1 4 1 1768 2 4 7 3 SN4924...

Page 61: ...61 Appendix C Port pin outs Chapter contents Introduction 61 Console port 61 Ethernet 10Base T and 100Base T port 61 Sync Serial port 62 FXS and FXO ports 63 ...

Page 62: ...19 EIA 561 RJ 45 8 pin port Note Pins not listed are not used Ethernet 10Base T and 100Base T port Figure 20 Model SN4900 Ethernet port Note Pins not listed are not used 6 DSR 1 CD 4 DTR 5 SG 2 RD driven 3 TD received 8 CTS 7 RTS 1 2 3 4 5 6 7 8 DSR DTR are internally wired together RJ 45 Jack Signal Name DB 9 RJ 45 Jack TX Transmit Data TX Transmit Data RX Receive Data 4 5 RX Receive Data 7 8 1 2...

Page 63: ... Description 1 Frame Ground 2 TD a to DCE 3 RD a from DCE 4 RTS to DCE 5 CTS from DCE 6 DSR from DCE 7 Signal Ground 8 CD from DCE 9 RC b from DCE 11 XTC b to DCE 12 TC b from DCE 14 TD b to DCE 15 TC a from DCE 16 RD b from DCE_ 17 RC a from DCE 20 DTR to DCE 24 XTC a to DCE Table 15 X 21 serial port signals DB 15 connector Pin Description 1 Signal Ground 8 DTE Common Return 2 Transmit to DCE 3 C...

Page 64: ...Green Whitee Blue Ring 3 3 White Brown Blue Tip 4 Pair 4 36 Brown White Blue Ring 4 4 White Slate Blue Tip 5 Pair 5 37 Slate White Blue Ring 5 5 Red Blue Blue Tip 6 Pair 6 38 Blue Red Blue Ring 6 6 Red Orange Blue Tip 7 Pair 7 39 Orange Red Blue Ring 7 7 Red Green Blue Tip 8 Pair 8 40 Green Red Blue Ring 8 8 Red Brown Blue Tip 9 Pair 9 41 Brown Red Blue Ring 9 9 Red Slate Blue Tip 10 Pair 10 42 Sl...

Page 65: ...lue Tip 24 Pair 24 56 Brown Purple Blue Ring 24 24 Purple Slate Blue Tip 25 Pair 25 57 Slate Purple Blue Ring 25 25 White Blue Orange Tip 26 Pair 26 58 Blue White Orange Ring 26 26 White Orange Orange Tip 27 Pair 27 59 Orange White Orange Ring 27 27 White Green Orange Tip 28 Pair 28 60 Green Whitee Orange Ring 28 28 White Brown Orange Tip 29 Pair 29 61 Brown White Orange Ring 29 29 White Slate Ora...

Page 66: ...lue Tip 6 Pair 6 31 Blue Red Ring 6 6 Red Orange Tip 7 Pair 7 32 Orange Red Ring 7 7 Red Green Tip 8 Pair 8 33 Green Red Ring 8 8 Red Brown Tip 9 Pair 9 34 Brown Red Ring 9 9 Red Slate Tip 10 Pair 10 35 Slate Red Ring 10 10 Black Blue Tip 11 Pair 11 36 Blue Black Ring 11 11 Black Orange Tip 12 Pair 12 37 Orange Black Ring 12 12 Black Green Tip 13 Pair 13 38 Green Black Ring 13 13 Black Brown Tip 1...

Page 67: ... 21 46 Blue Violet Ring 21 21 Violet Orange Tip 22 Pair 22 47 Orange Violet Ring 22 22 Violet Green Tip 23 Pair 23 48 Green Violet Ring 23 23 Violet Brown Tip 24 Pair 24 49 Brown Violet Ring 24 24 Violet Slate Tip 25 Pair 25 50 Slate Violet Ring 25 25 Table 17 Band marked color codes for the 50 pin RJ 21X connector Continued Wire Color Code Tip Ring Pair Number 50 Pin Positions Main color Stripe ...

Page 68: ...68 Appendix D Factory Configuration Chapter contents Introduction 68 ...

Page 69: ...P network 192 168 1 0 255 255 255 0 include 1 192 168 1 10 192 168 1 99 lease 2 hours default router 1 192 168 1 1 domain name server 1 192 168 1 1 context ip router interface eth0 ipaddress dhcp use profile napt NAPT tcp adjust mss rx mtu tcp adjust mss tx mtu interface eth1 ipaddress 192 168 1 1 255 255 255 0 tcp adjust mss rx mtu tcp adjust mss tx mtu context ip router dhcp server use DHCP port...

Page 70: ...70 Appendix E End user license agreement Chapter contents End User License Agreement 70 1 Definitions 70 2 Title 70 3 Term 70 4 Grant of License 70 5 Warranty 70 6 Termination 71 7 Other licenses 71 ...

Page 71: ...nated Equipment at a site owned or leased by the End User B The End User may copy licensed Program s as necessary for backup purposes only for use with the Des ignated Equipment that was first purchased or used or its temporary or permanent replacement C The End User is prohibited from disassembling decompiling reverse engineering or otherwise attempt ing to discover or disclose the Program s sour...

Page 72: ...ate this Agreement should End User violate any of the provi sions of section 4 Grant of License on page 71 C Upon termination for A or B above or the end of the Term End User is required to destroy all copies of the licensed Program s 7 Other licenses The Program may be subject to licenses extended by third parties Accordingly Patton Electronics Company licenses the Programs subject to the terms a...

Page 73: ...73 Appendix F Installation checklist Chapter contents Introduction 73 ...

Page 74: ...ation checklist Task Verified by Date Network information available recorded in site log Environmental specifications verified Site power voltages verified Installation site pre power check completed Required tools available Additional equipment available All printed documents available SmartWare release build number verified Rack desktop or wall mounting of chassis completed Initial electrical co...

Page 75: ...75 Appendix G Accessories Chapter contents Introduction 75 ...

Page 76: ...to DB 15 male cable Sync serial X 21 port EMEM216006 64 pin telco to open end cable 6 ft 1 8 m 64 pin FSX port 10493264 10 50 pin telco to open end cable 20 ft 6 m 10 3096TM50 20 50 pin telco 16 ends RJ 11 cable 6 ft 1 8 m 10 3096TM50 16RJ11 6 50 pin telco 16 ends RJ 45 cable 6 ft 1 8 m 10 3096TM50 16RJ45 6 50 pin telco 50 pin telco cable 6 ft 1 8 m 10 3096TM50 50 6 DB 25 male to M 34 female cable...

Reviews: