Using a browser to complete Model 2616RC configuration
43
Model 2616RC T-DAC User Manual
3 • Configuring the T-DAC for operation
2.
Click the
System Clocking
hyperlink on the
2616RC Configuration Menu
to open the
System Clocking
Configuration
page (see
figure 30
).
Figure 30. System Clocking Configuration page, example 2
3.
For
Clock Reference
select
secondary(2)
or
slave(3)
.
Note
If slave is selected you will not be able to configure the main or fall-
back reference. If you selected
slave(3)
, go to step 6. Otherwise, con-
tinue on to step 4.
4.
If you selected
secondary(2)
in step 3, for
Main Reference
select
system(500)
.
5.
For
Fallback Reference
select
wan-1(1)
.
6.
Click the
Submit Query
button shown in
figure 31
.
Figure 31. Clock Reference Submit Query button
7.
Select
enable(1)
to enable the fallback reference clock.
8.
Click the
Clock Fallback
Submit Query
button shown in
figure 32
.
Figure 32. Clock Reference Submit Query button