T1/E1 port test modes
64
Model 2616RC T-DAC User Manual
5 • Troubleshooting and maintenance
T1/E1 port test modes
The 2616RC offers a number of diagnostics tools to test operation and performance of the T1/E1 ports and
line. Diagnostics include DSX1 payload loop and DSX1 line loop.
DSX1 payload loop (dsx1PayloadLoop)
When activated, the received signal at the selected T1/E1 port, will be looped through the 2616RC (see
figure 54
). Typically the received signal is looped back for retransmission after it has passed through the
device's framing function (framing is terminated and then regenerated).
Figure 54. Payload loopback
To activate payload loop, do the following:
1.
Click on the
Modify Configuration
link of the T1/E1 port to be placed under test
2.
Locate the
Loopback Configuration
drop down menu
3.
Select
Payload Loop
and click on the
Submit Query
button on the right.
To deactivate payload loop, set the
Loopback Configuration
drop down menu to
NoLoop
.
READY
Front panel
Blue
On
Card ready for removal from Patton ForeFront chassis.
Off
Card not ready for removal from Patton ForeFront chassis.
Do not remove card from chassis.
ALARM
Rear blade Yellow On solid A minor alarm condition has been detected.
Flashing A major alarm condition has been detected.
Off
The Model 2616RC is operating normally. No action
recommended.
READY
Rear blade
Blue
On
Card ready for removal from Patton ForeFront chassis.
Off
Card not ready for removal from Patton ForeFront chassis.
Do not remove card from chassis.
Table 7. LED definitions (Continued)
LED
Location
Color
Status
Meaning