6 • DAX
Model 3120 RAS Administrators’ Reference Guide
50
Configuring the DAX
•
netref-2(102)—Use to obtain system timing from a slave circuit.
•
internal(200)—Use internal free-run oscillator for the system clock
•
external(300)—Not currently implemented.
Clock Status (daxClockFailure)
The clock status indicates alarm conditions relating to the system clock. If there are no alarms, the DAX page
will indicate No Alarms (see figure 20 on page 48). Should one or more alarms be present, an Alarms Present
message will be displayed with the following list of potential clock failures (figure 21).
•
Main Reference Fail(1)—The main clock reference has failed
•
Fallback Reference Fail(2)—The fall back clock reference has failed
•
Master System Fail(4)—The Master System clock has failed
•
Secondary System Fail(8)—The Secondary System clock has failed.
Figure 21. DAX Clock Status alarm condition
Summary of Contents for 3120
Page 8: ...Contents Model 3120 RAS Administrators Reference Guide 8...
Page 12: ...About this guide Model 3120 RAS Administrators Reference Guide 12...
Page 134: ...8 Dial Out Model 3120 RAS Administrators Reference Guide 134 An example section of dialout...
Page 140: ...9 Callback Access Server Administrators Reference Guide 140 Dialout...
Page 176: ...13 Filter IP Model 3120 RAS Administrators Reference Guide 176 An example of using a filter...
Page 226: ...17 MFR Version 2 Model 3120 RAS Administrators Reference Guide 226 MFR Version 2 Modify...
Page 238: ...19 SNMP Model 3120 RAS Administrators Reference Guide 238 Out...
Page 304: ...25 License Model 3120 RAS Administrators Reference Guide 304 End User License Agreement...
Page 309: ...309 Appendix B MIB trees Chapter contents Model 2960 MIB Tree Structure 310...