DSP information window
155
Model 3120 RAS Administrators’ Reference Guide
11 • Digital Signal Processing (DSP)
Instance First State (dspStatefirst)
Identifies the current state of the first instance of the DSP.
•
hardwareFailure(1)—During power up a self test routine detected a problem with this DPS. It will not be
booted with code or used for calls.
•
pendingBoot(2)—Software on this DSP has stopped acting properly. This DSP will not be used for calls. At
the next convenient time the DSP will be rebooted.
•
booting(3)—The DSP has just been loaded with code and we are now waiting for an indication from the
DSP that the code loaded properly and is running.
•
hwReseted(4)—The DSP is reset.
•
swLoaded(5)—Software is downloaded to the DSP or DSP group.
•
unavailable(7)—The instance is fully operational and could be used to take a call except that the adminis-
trator has indicated that this instance should not be used.
•
suspect(9)—The instance is operational and could be used to take a call. But, we have seen a number of
consecutive failures so it will not be used until no other available instances can be found. A successful call
will place this instance back into the available state.
•
available(10)—The instance is fully operational and can be used to take a call
Instance First Used By (dspUseFirst)
Identifies whether the first instance is in use or free.
Instance Second State (dspStateSecond)
Identifies the current state of the second instance of the DSP. See dspStateFirst for parameter values.
Instance Second Used By (dspUseSecond)
Identifies whether the second instance of the DSP is in use or free.
Call Statistics
This portion of the DSP information window (see figure 64 on page 154) shows the statistics of the individual
DSP.
Originating Calls (dspOriginatingCalls)
The number of calls the DSP initiates for outbound calls.
Answering Calls (dspAnsweringCalls)
The number of calls answered regardless if the call was successfully completed.
Successful Connects (dspSuccessfulConnects)
The number of calls that successfully connected.
Failed Connect (no far modem) (dspFailedConnectPreV8)
The number of calls that failed before modulation V8 was completed.
Summary of Contents for 3120
Page 8: ...Contents Model 3120 RAS Administrators Reference Guide 8...
Page 12: ...About this guide Model 3120 RAS Administrators Reference Guide 12...
Page 134: ...8 Dial Out Model 3120 RAS Administrators Reference Guide 134 An example section of dialout...
Page 140: ...9 Callback Access Server Administrators Reference Guide 140 Dialout...
Page 176: ...13 Filter IP Model 3120 RAS Administrators Reference Guide 176 An example of using a filter...
Page 226: ...17 MFR Version 2 Model 3120 RAS Administrators Reference Guide 226 MFR Version 2 Modify...
Page 238: ...19 SNMP Model 3120 RAS Administrators Reference Guide 238 Out...
Page 304: ...25 License Model 3120 RAS Administrators Reference Guide 304 End User License Agreement...
Page 309: ...309 Appendix B MIB trees Chapter contents Model 2960 MIB Tree Structure 310...