Operating Status Variables
19
Model 3120 RAS Administrators’ Reference Guide
2 • Home
Operating Status Variables
There are seven system variables which describe the immediate operating status access server. These variables
are shown in figure 4 and are described in the following sections.
Figure 4. STATUS menu
Active Calls (diActive)
This number, ranging from 0 to 120 displays the total number of calls being processed (connecting, online,
authenticating, and so on) in the access server at the time the HOME page was displayed.
Peak Active Calls (diMaxActive)
The maximum number of active calls seen at one time since the access server was powered on.
Total Calls (diTotalCallAttempts)
The total number of calls attempted since the last boot of the box.
DSPs Not Working (dspFailed)
This number should always be zero. The DSPs in the access server are arranged as a resource pool and called
upon at ring-time. If a DSP fails to respond to the access server’s CPU, it is determined to have failed, at which
point the CPU will remove the DSP from the resource pool. If an incoming call attempts to access the failed
DSP, the RAS will answer, then terminate the call (to a person monitoring the failed call through a telephone
handset, he or she will hear only silence during the call, ending with a faint click as the call is terminated). One
symptom indicating that a DSP has failed is if the access server is not handling as many calls as it normally does.
Total DRAM Detected (boxDetectedMemory)
This number shows the total number of bits of installed and available DRAM.
Running Since Last Boot (sysUpTime)
This tells you how long the access server has been running since the it was last reset. It displays the number of
hours and rolls over after 1,193 hours (497 days).
Summary of Contents for 3120
Page 8: ...Contents Model 3120 RAS Administrators Reference Guide 8...
Page 12: ...About this guide Model 3120 RAS Administrators Reference Guide 12...
Page 134: ...8 Dial Out Model 3120 RAS Administrators Reference Guide 134 An example section of dialout...
Page 140: ...9 Callback Access Server Administrators Reference Guide 140 Dialout...
Page 176: ...13 Filter IP Model 3120 RAS Administrators Reference Guide 176 An example of using a filter...
Page 226: ...17 MFR Version 2 Model 3120 RAS Administrators Reference Guide 226 MFR Version 2 Modify...
Page 238: ...19 SNMP Model 3120 RAS Administrators Reference Guide 238 Out...
Page 304: ...25 License Model 3120 RAS Administrators Reference Guide 304 End User License Agreement...
Page 309: ...309 Appendix B MIB trees Chapter contents Model 2960 MIB Tree Structure 310...