Wireless Control Unit
28
7. Operation
7.4.2.1. One-shot Output Clear
•
When operating in One-shot Mode, the output continuous state can be canceled by the receiving product.
•
To cancel the output continuous state, execute Clear Input (OFF→ON) to the receiver or repeater that is
maintaining the output.
• Read "7.2. About the DIP Switches and Reset Button" (
page 20) before handling the DIP switches.
ON Input
OFF Input
Clear Inpu
t
ON Input
WIO
Transmitter
ON Input
OFF Input
Hold output
ON output
OFF output
ON output
OFF output
OFF Input
Repeater
WIO
ON output
OFF output
ON output
OFF output
Hold output
Clear Inpu
t
Receiver
WIO
12 seconds
Detection timing
12 seconds
12 seconds
12 seconds
Setting
Setting
Function
DIP Switch
Function
DIP Switch
Detection timing
Detection timing
Detection timing
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Output for
12 seconds
ON
ON
ON
Output for
12 seconds
Point
●
One-shot Output Clear operates independently for each product. (One-shot Output Clear of the repeater and of the
receiver are not linked.)
●
One-shot Output Clear is detected as input OFF→ON (detection timing shown in the figure).
●