RP-330 Technical Manual
11
1.8 Internal Buffer
1)
Receive buffer: 20 K Bytes
1.9 Electrical Characteristics
1) Supply voltage:
+24 VDC ± 7%
2)
Current consumption (at 24V):
Operating: Approx. 1.5A(at ASCII Printing)
Peak:Approx. 10A(at print duty 100%, For 10 seconds or less)
Stand-by: Approx. 0.03A
1.10 EMI and Safety Standards Applied
1)
Europe:
EN55022 : 2006+A1 : 2007 (CLASS B)
EN55024 : 1998+A1 : 2001+A2 : 2003
EMS – EN61000-3-2, EN61000-3-3
Safety Standard:
UL 60950-1
2) North America:
EMI - FCC Part#15 Class A
Safety Standards- UL60950-1
1.11 Reliability
1) MCBF:
60 million lines
(based on an average printing rate of 12.5% with paper thickness in the range 65
㎛
to 75
㎛
).
35 million lines
(based on an average printing rate of 12.5% with paper thickness in the range 76
㎛
to 150
㎛
)
2) Cutter Life:
the cutter performs 1,500,000 cuts with thickness 65
㎛
, and/or 300,00cuts with
thickness 100
㎛
to the paper
1.12 Environmental Conditions
1) Temperature:
Operating:
5
to 45
C
Storage:
-20
to 60
C
(except for paper)
2) Humidity:
Operating:
10 to 90%RH
Storage:
10 to 90%RH (except for paper)