ASLD2200 - Instruction Manual
5.2 Electrical Connections
Number
Function
Colour of
Internal Wiring
1
Remote Up Switch
White/Black
2
Remote Down Switch
Orange/Black
3
Remote Switch Common
Yellow/Black
4
4-20 mA Hi (+)
5
4-20 mA Lo (-)
6
Regulated 12v DC Output
7
0v DC
8
Limit Relay, 0% and/or 100%
9
Limit Relay, 0% and/or 100%
10
0v DC
11
Sensor Lo
Blue
12
Sensor 12v
Brown
13
5v DC to Encoder
Red
14
Input 1 from Encoder
Blue
15
Input 2 from Encoder
Yellow
16
0v DC to Encoder
Black
17
Nominal 18v DC to Motor (+ve)
Green
18
Nominal 18v DC to Motor (-ve)
Red/Brown
19
Not Used
20
Not Used
21
To mains isolator
Red/Brown
22
To mains isolator
Red/Brown
23
Earth
24
No connection
25
Neutral
26
Live
The ASLD2200 requires a mains power supply to operate this can be either 115 or 230v AC.
Unless specifically advised to do so, do not make changes to the internal wiring.
103370IM Issue 10 Date 19/03/2018
Page 13 of 30
PCBA SHOWING TERMINATION DETAILS