ASLD2200 - Instruction Manual
10 Maintenance
10.1 General Precautions
Do not lift the unit by the drum
Check that the unit is bolted firmly to the support bracket
Warning: Isolate the mains supply before commencing any maintenance to the electronics enclosure; the external
switch does not isolate the electronics
10.2 Routine Maintenance
The sensor will require routine cleaning; the frequency of cleaning is site dependent and should be determined by
observation of the sensor during the first few weeks of operation.
Typically the sensor should be cleaned once per fortnight, although on many sites once per month is sufficient.
The sensor can be cleaned using a soft cloth; no special cleaning materials are required.
Care must be taken to ensure that no loops of cable are displaced during cleaning and the sensor should be lowered
carefully into the tank after cleaning.
10.3 Removal of the Printed Circuit Board Assembly
1. Unscrew thumb screws and remove Front panel
2. Unscrew 3 pozi screws and remove terminal cover.
103370IM Issue 10 Date 19/03/2018
Page 19 of 30
FRONT PANEL SCREWS
1
2