Important Considerations
Maximum Cable Length:
The maximum cable length for power delivery to the barrier
is 25 meters. We recommend using a 1.5 mm cross-section cable for optimal
performance.
Single Barrier Power:
Each barrier must be connected to its dedicated power supply
via a separate cable. Do not attempt to power multiple barriers with a single supply, as
it may compromise their operation.
Voltage Limit:
It is crucial to ensure that the voltage supplied to the barrier never
exceeds 11V. Exceeding this limit can result in damage to the barrier system.
5.5.3. Technical Specification
Parameter
Value
Input voltage:
85 Vac to 264 Vac
Input voltage frequency:
47 Hz to 63 Hz
Efficiency:
83 %
Input current:
1.2 A (115 Vac) 0.8A (230 Vac)
Inrush current:
30A (115 Vac) 60A (230 Vac)
Output voltage:
10.8 Vdc - 13.8 Vdc
Continuous output current:
4.5 A
Rated power:
54 W
No load power:
0.3 W