![Parker ViX250CM User Manual Download Page 181](http://html1.mh-extra.com/html/parker/vix250cm/vix250cm_user-manual_755859181.webp)
6. COMMAND REFERENCE
173
USE
Use
Syntax
Units
Range of ‘n’
Default
See also
aUSE(profile)
-
1 to 8
-
PROFILE
Description
The USE command copies the pre-defined profile to the current move
parameters.
Properties
Immediate or buffered, can be used in labelled block, not saved by SV
Example
1PROFILE1(200,20,1500,25)
;define profile 1
1PROFILE2(150,200,4800,45)
;define profile 2
1USE(2)
;use motion profile 2
WARNING
If you attempt to use an undefined PROFILE, PROFILE0 is used
with no error indication.
V
Velocity
Syntax
Units
Range of ‘n’
Default
See also
aVn
see SCALE
0.001 to 50.000
1
PROFILE
SCALE
Description
Velocity command V sets or reports the programmed velocity of the motor.
Properties
Immediate or buffered, can be used in labelled block, saved by SV
Example
To set the velocity of axis 3 to 25 rps, type......................
3V25
To report the current velocity of axis 3, type ....................
3V
The controller responds with............................................
No units are reported.
*25.0
Note
[1] A programmed value of velocity can be overwritten by a PROFILE
command once the USE command has been issued, but subsequent values
of velocity can be programmed to override the value in use.
[2] With SCALE enabled, a maximum value of 5000 (user-units) is permitted.
[3] If a value is entered that requests a velocity greater than the maximum
velocity set in the MOTOR command, *E will be returned.
Summary of Contents for ViX250CM
Page 3: ......
Page 52: ...44 VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE...
Page 102: ...VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE 94...
Page 206: ...198 VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE...
Page 218: ......