Compax3
device description
C3I10T10
66
192-120100 N16 C3I10T10 - December 2010
3.8.3.4
Command value release X12/7="24VDC"
This input effects the state of the power stage and therefore that of the motor:
X12/7="0V":
Set motor to command value=0
With a rotating motor, this will be decelerated to a speed of 0 via
a settable deceleration ramp.
X12/7="24 V DC":
Current setpoint value active
The motor will be accelerated via a settable acceleration ramp to
the predefined setpoint value.
Prerequisite: X12/6 "Energize the motor" = 24VDC
Setting values for "Setpoint value release":
See also
Setpoint control
(see on page 107).