Parker EME
Technical Characteristics
192-120100 N16 C3I10T10 - December 2010
215
Output data Compax3Hxxx at 3*400VAC
Controller type
H050V4
H090V4
H125V4
H155V4
Output voltage
3x 0-400V
Nominal output current
50Arms
90Arms
125Arms
155Arms
Pulse current for 5s *
75Arms
135Arms
187.5Arms 232.5Arms
Power
35kVA
62kVA
86kVA
107kVA
Switching frequency
8kHz
8kHz
8kHz
8kHz
Power loss for In
880W
900W
1690W
1970W
* during low speeds, the overload time is reduced to 1s. Limit:
< 2.5 electric rev/s (= actual revolutions/s * number of pole pairs) resp. >2.5 pitch/s
Output data Compax3Hxxx at 3*480VAC
Controller type
H050V4
H090V4
H125V4
H155V4
Output voltage
3x 0-480V
Nominal output current
43Arms
85Arms
110Arms
132Arms
Pulse current for 5s*
64.5Arms 127.5Arms 165Arms
198Arms
Power
35kVA
70kVA
91kVA
109kVA
Switching frequency
8kHz
8kHz
8kHz
8kHz
Power loss for In
850W
1103W
1520W
1800W
* during low speeds, the overload time is reduced to 1s. Limit:
< 2.5 electric rev/s (= actual revolutions/s * number of pole pairs) resp. >2.5 pitch/s