Parker EME
Setting up Compax3
192-120100 N16 C3I10T10 - December 2010
105
Setting values:
Increments per motor revolution / pitch
Unit: Increments
Range:
Standard value: 1024
Number of steps per motor revolution / pitch
Invert Motor Rotation/Direction Polarity
Unit:
-
Range: no / yes
Standard value: no
Reverse direction inverts the sense of rotation, i.e. the direction of movement of the motor
is reversed in the case of equal setpoint.
4.1.7.4
Step/Direction Input 24V
Increments per motor revolution / pitch
Unit: Increments
Range:
Standard value: 1024
Number of steps per motor revolution / pitch
Invert Motor Rotation/Direction Polarity
Unit:
-
Range: no / yes
Standard value: no
Reverse direction inverts the sense of rotation, i.e. the direction of movement of the motor
is reversed in the case of equal setpoint.
4.1.7.5
Encoder input RS422
A\
A
B\
B
RS422
The zero pulse is not evaluated!
Increments per motor revolution / pitch
Unit: Increments
Range:
Standard value: 1024
Number of steps per motor revolution / pitch
Invert Motor Rotation/Direction Polarity
Unit:
-
Range: no / yes
Standard value: no
Reverse direction inverts the sense of rotation, i.e. the direction of movement of the motor
is reversed in the case of equal setpoint.