Setting
up Compax3
C3I10T10
142
192-120100 N16 C3I10T10 - December 2010
4.4.7.
Alignment of the analog inputs
In this chapter you can read about:
.............................................................................................................142
Gain alignment ...............................................................................................................142
There are two possibilities to align the analog inputs in the optimization window:
Wizard-guided under commissioning: Commissioning functions (click on the
yellow triangle with the left mouse button:
Caution!
This wizard guided automatic alignment does not work if you bridge Ain+ with
Ground for the alignment!
In this case, please make a manual alignment as described below.
or
by directly entering under optimization: Analog input
4.4.7.1
Offset alignment
Performing an offset alignment when working with the ±10V analog interface in the
optimization window under optimization: Analog input Offset [170.4].
Enter the offset value for 0V input voltage.
The currently entered value is shown in the status value "analog input" (optimizing
window at the top right) (unit: 1
≡
10V). Enter this value directly with the same sign
as offset value.
The status value "analogue input" shows the corrected value.
4.4.7.2
Gain alignment
Performing an offset alignment when working with the ±10V analog interface in the
optimization window under optimization: Analog input: Gain [170.2].
A gain factor of 1 has been entered as default value.
The currently entered value is shown in the status value “analog input” (optimizing
window at the top right).
The status value "analogue input" shows the corrected value.