9
Stainless Steel Air Motors
P1V-S
Air motors
Air motor
P1V-S002
P1V-S008
P1V-S012
P1V-S020
P1V-S030
P1V-S060
P1V-S120
Air flow required, Nl/s
1,7
3,8
5,0
6,3
8,0
14,5
7
Air flow required, Nl/min
10
30
300
380
480
870
160
Min. internal diameter of pipe, mm
4
4
6
10
10
1
19
Choice of air treatment unit: recommended min. air flow in litres/minute at 7,5 bar air supply and 0,8 bar pressure drop
110
255
330
420
530
960
1780
Choice of valve: recommended min. air flow in Qn in litres/minute
(Qn is the flow through the valve at 6 bar supply pressure and 1 bar pressure drop over the valve).
123
280
360
440
660
1080
2160
Drilling motors
Drilling motor
P1V-S008
P1V-S017
P1V-S025
P1V-S040
Air flow required, Nl/s
3,8
5,0
6,3
8,0
Air flow required, Nl/min
30
300
380
480
Min. internal diameter of pipe, mm
4
6
6
10
Choice of air treatment unit: recommended min. air flow in litres/minute at 7,5 bar air supply and 0,8 bar pressure drop
255
330
420
530
Choice of valve: recommended min. air flow in Qn in litres/minute
(Qn is the flow through the valve at 6 bar supply pressure and 1 bar pressure drop over the valve).
280
360
440
580
Grinding and milling motors
Motor
Grinding
Grinding
Milling
P1V-S009
P1V-S020
P1V-S040
Air flow required, Nl/s
,0
6,3
8,0
Air flow required, Nl/min
10
380
480
Min. internal diameter of pipe, mm
4
6
10
Choice of air treatment unit: recommended min. air flow in litres/minute at 7,5 bar air supply and 0,8 bar pressure drop
135
420
530
Choice of valve: recommended min. air flow in Qn in litres/minute
(Qn is the flow through the valve at 6 bar supply pressure and 1 bar pressure drop over the valve).
145
440
580
Summary of Contents for 1P1V-S020A00005
Page 66: ...66 Stainless Steel Air Motors P1V S...
Page 67: ......