19
Stainless Steel Air Motors
P1V-S
For the P1V-S012, P1V-S020, P1V-S030 and P1V-S060
series
The temperature is measured on the metal surface next to the
seal around the output shaft on all P1V-S01, P1V-S00,
P1V-S030 and P1V-S060 motors
II2 GD c IIC T6 (80 °C) X
II2 GD c IIC T5 (95 °C) X
Seal
Planetary
gearbox
Motor part
45
Planetary
gearbox
Motor part
x
Marking of products
For all P1V-S012, P1V-S020, P1V-S030 and P1V-S060
For the P1V-S120
C
ommunatuté
E
uropéenne = EU
CE
marking shows that as a manufacturer, Parker
Hannifin meets the guidelines specified by the EU
Ex
means that this product is intended for use in a
potentially explosive area
II
stands for the equipment group (I = mines and II =
other places liable to be endangered)
2GD
stands for equipment category
2G
means the equipment can be used in zones 1 and
where there is a risk involving gas, vapour or mist of
combustible liquids and
2D
in zones 1 and where
there is a risk involving dust .
2GD
means the equipment can be used in zones 1, ,
1 and .
c
Safe design (prEN 13463-5)
IIC
Explosion group, P1V-S air motors are tested to the
highest standards in terms of test gases, and can be
installed in the presence of all gases without restric-
tion.
T6
If equipment is in temperature class
T6
, the maximum
surface temperature must not exceed 85 °C. (To guar-
antee this, the product has been tested to ensure that
the maximum is 80 °C. This provides a safety margin
of 5 °K.)
T5
If equipment is in temperature class
T5
, the maximum
surface temperature must not exceed 100 °C. (To
guarantee this, the product has been tested to ensure
that the maximum is 95 °C. This provides a safety
margin of 5 °K.)
(80 °C)
Maximum permitted surface temperature on the motor
in atmospheres containing potentially explosive dust.
X
Note special conditions
Test certificate number IBExU04ATEXB004 X from
IBExU Institut für Sicherheitstechnik GmbH, D-09599
Freiberg, Germany
Motor
x [mm]
P1V-S00A0011
133
P1V-S00A0006
133
P1V-S030A003
146
P1V-S030A0010
147,5
The maximum temperature is reached after approximately 1,5
hours of operation, and the difference in temperature between
the motor and the ambient temperature must not exceed 40
°C.
If the temperature difference at the seal of a P1V-S012, P1V-S020,
P1V-S030 or P1V-S060 exceeds 40 °C, you should stop the motor
immediately and contact Parker Hannifin.
The following applies to the P1V-S120 series:
The temperature is measured on the metal surface at a point
45 mm from the port end of the motor housing, on all P1V-
S10.
Motors P1V-S020A0011, P1V-S020A0006,
P1V-S030A0023 and P1V-S030A0010
The maximum temperature is reached after approximately 1,5
hours of operation, and the difference in temperature between
the motor and the ambient temperature must not exceed 55
°C.
If the temperature difference at this point on a P1V-S120 exceeds
55 °C, you should stop the motor immediately and contact Parker
Hannifin.
Summary of Contents for 1P1V-S020A00005