Trouble Shooting
CAUTION
Before any maintenance work on the compressor, make sure there is not air inside, under pressure.
Every time you stop the compressor, ALWAYS open the manual drains so as to remove condensate.
Maintenance work on the compressor must always be done with the compressor stopped and disconnected from
the mains supply. Never forget to open the manual drains, after stopping the compressor.
Especially when you are planning to clean the solenoid valves (auto drains version), always turn off the main
electrical supply.
You must always have in mind, if you disconnect the coil of the solenoid valves, without turning off the electrical
supply, it will be destroyed immediately!!!
Trouble
Cause
Remedy
unit does not start / no
indication on the
control panel
Electric circuitry faulty
Check main fuses, auxiliary fuses,
terminal connections, wire leads.
Thermal switch enabled
Motor does not start
1.Motor protections has activated
2.Active errors forbid the motor start
1. Reset the motor trip and check the
motor.
2. Reset the errors , eliminate the
cause of the errors
The motor start with
difficulty
1. Unstable power supply
2. Pressure remain in the stages
3.inlet pressure high
4.Star-delta switching incorrect
1. Check and stabilize the power
supply.
2. a. too short time between stop –
start.
b. check drains function.
3. Check inlet valve and inlet pressure
regulator setting.
4. check star/delta function
Wrong rotation
direction
Phases reversed
Change phases
Main Motor protection
has activated
1. unstable power supply
2. High power consumption
1. Check and stabilize the power
supply.
2.a.motor faulty wiring
b. motor overload via bearings
c. compressor block overload
d. high inlet pressure
Decreased
performance of the
compressor
1
.Blocked air intake filter
1
.Clean - Replace
2
.1
st
stage, 2
nd
stage or 3
rd
stage valves,
are not properly closed
2
.Check the intermediate pressures
3
.1
st
stage, 2
nd
stage or 3
rd
stage Piston
rings worn
3
.Replace
4
.Worn cylinders
4
.Replace
5
.Pipes leaking
5
.Tighten and reseal
6.
Solenoid valves stuck open
6.
Clean - Replace
7.
Unstable power supply - voltage
7.
Check power supply fuse box