Option 2 (standard version from begin of 2018):
Ø110 x 740 (max. working pressure 480 bar)
Replacement of active carbon – molecular sieve cartridge
1.
Unscrew the filter head counter clockwise.
2.
Remove the filter head and the spring.
3.
Place the
special handle
on top of the A.C.-M.S cartridges.
4.
Remove the A.C.-M.S. cartridges by pulling upwards with the
special handle.
Before throwing away the
used cartridge, do not forget to remove the cartridge connector.
5.
Clean the inside of the filter housing with a clean cloth.
6.
Remove the new A.C.-M.S. cartridges from their protective case. Be sure that packaging is not punctured.
If it is damaged do not use it.
7.
Lay a small amount of silicone grease on the o-ring of the new A.C.-M.S. cartridges.
8.
Screw the two A.C.-M.S. cartridges together so as to create a solid body.
9.
Replace the o-ring of the cartridge connector, lay a small amount of silicone grease on the new o-ring and
then screw the connector on the bottom A.C.-M.S. cartridge.
10.
Place the new A.C.-M.S. cartridge in the filter housing and screw it down by hand on the coalescing
connector (see also drawing nr. B).
11.
Lay a small amount of silicone grease on the o-rings of the filter head. If there is a trace of damage on the
o-rings, replace.
12.
Install the spring in between the filter head and the cartridge.
13.
Screw the filter head carefully by hand with light pressure until it fits evenly to the filter housing.
Do not screw really tight, while screwing cartridges or connectors inside filter’s housing.