5.3.
Display Structure and Menu Navigation
5.3.1.
Display Item Structure
All value, parameter or option selection displays are grouped into menu lists. Items are assigned to a list according
to type and classification. Items that can be used to select options or modify functions are assigned to ‘menu mode’
lists. Items that an operator may require to view during routine operation, detected pressure or temperature
values for example, are assigned to the normal operational mode list. Lists are identified by page number, the
normal operational display list is page 0. All parameters and options are assigned to menu mode pages 1 or higher.
All Page 0 items are view only and cannot be adjusted.
5.3.2.
Normal Operational Mode (Page 0)
At controller initialization, all display elements and LED indicators are switched on for three seconds, the display
will then show the software version code for a further 3 seconds before initialisation is complete and the normal
operating display (Page 0) is shown. In page 0 ‘normal operational display mode’ the Display Field will show the
final delivery pressure continuously and the Item and Value Fields will initially show the Information Item display
for 35 seconds before reverting to the default temperature display item. All available Item and Value field option
displays (temperatures, pressures, hours counters) can be selected using the Up or Down buttons at any time. The
Item display will revert to the default item after 35 seconds if no further selection is made. Pressing the Enter
button will lock any selected Item display and inhibit return to the default display. When an Item display is locked
the lock key symbol will slow flash. To unlock an Item display press Up or Down to view an alternative Item display
or press Reset or Escape. In page 0 Escape will select the Status Information Item display and Reset will select any
active fault code display or the Status Information Item display if no faults are active. Unless a selected Item display
is locked, the display will automatically jump to the Status Information Item display at key status change events.
The timeout period before returning to the default Item display is modified in some instances to enable the full
range of a set countdown timer to be shown. No Item values, options or parameters can be adjusted in page 0. If a
fault condition occurs the fault code becomes the first list item and the display will automatically jump to display
the fault code. More than one active fault code item can exist at any one time.
Access Code:
Access to page list displays higher than page 0 are restricted by access code. To access menu mode pages press UP
and DOWN together, an access code entry display is shown and the first code character will flash. Use PLUS or
MINUS to adjust the value of the first code character then press ENTER. The next code character will flash; use UP
or DOWN to adjust then press ENTER. Repeat for all four code characters. If the code number is less than 1000 then
the first code character will be 0(zero). To return to a previous code character press ESCAPE. When all four code
characters have been set to an authorized code number press ENTER. Access to certain menu mode pages is
dependent on authority level determined by the access code used. An invalid code will return the display to normal
operational mode; page 0.
ACCESS LEVEL CODE = 0100