5.5.
Immediate Stop Shutdown Errors
5.5.1
Digital input errors
Er:0010 E
Emergency stop OR low oil level.
Er:0020 E
1
st
stage pressure switch. Pressure high or switch fault.
Er:0070 E
main motor or fan motor overload. Thermal switch enabled
Er:0080 E
2
nd
stage pressure switch. Pressure high or switch fault.
Digital input errors when Humidity Control Device option is installed
Er:0010 E
Emergency stop OR low oil level (option).
Er:0020 E
1
st
stage pressure switch & 2
nd
stage pressure switch. Pressure high or switch
fault.
Er:0070 E
motor overload. Thermal switch enabled.
Er:0080 E
Humidity Control Alarm (option)
Digital input errors when Voltage Failure/Phase Rotation Device option is installed
Er:0010 E
Emergency stop OR low oil level (option).
Er:0020 E
1
st
stage pressure switch & 2
nd
stage pressure switch. Pressure high or switch
fault.
Er:0070 E
motor overload. Thermal switch enabled.
Er:0080 E
Voltage Failure/Phase Rotation Alarm (option)
5.5.2
Analog input errors
Er:0115 E
delivery pressure (4
th
stage) sensor fault
Er:0119 E
delivery pressure (4
th
stage) high
Er:0125 E
temperature (4
th
stage) sensor fault
Er:0129 E
temperature (4
th
stage) high
Er:0135 E
Inter-stage pressure (3
rd
stage) sensor fault
Er:0139 E
Inter-stage pressure (3
rd
stage) high
5.6
Controlled Stop Shutdown Errors
5.6.1
Special function service trips
Er:1814 E
OIL service due trip
Er:1824 E
final BA FILTER service due trip
Er:0821 E
low resistance, short circuit or short circuit to earth condition exists on an
analogue input or digital input (incorrect connection, cable fault or sensor fault)
5.7
Alarms
5.7.1
Analogue input alarms
Er:2118 A
delivery pressure (4
th
stage) high
Er:2128 A
temperature (4
th
stage) high
Er:2138 A
Inter-stage pressure (3
rd
stage) high
5.7.2
Special function alarms
Er:2816 A
power failure while compressor was in started state
5.8
Start Inhibits
Er:3123 S
Temperature (4
th
stage) below the set low temperature run inhibit level, controller will allow
motor start when temperature increases above the preset level
5.9
Special function service alarms
Er:4814 A
OIL service due alarm
Er:4824 A
final BA FILTER due alarm