5.1.2.
Fully Automatic mode
Fully Automatic mode can be set in Operation Menu P01 after entering the user level access code. Fully Automatic
is a mode of operation in which the delivery pressure controls compressor start and stop operation once the
operator has started the compressor. The motor is started and pressure will begin to rise. When the unload
pressure level is achieved, the compressor motor will stop and the compressor will remain active in a standby state.
The compressor motor will automatically start again when the delivery pressure falls below the load pressure level
or when there is a new operator request to start. This cycle will continue until the operator stops the compressor
by pressing the stop button, which means an exit of Fully Automatic mode.
REMARK:
When delivery pressure is below the unload level, but above the load level, the motor can be immediately started
again by pressing the start button. This will cause the compressor to start and increase pressure to the unload level
again without the need to wait for the pressure to decrease to the load level.
pressure
time
internal pressure
delivery pressure
unload pressure
start button
unload
pressure
load
pressure
start button
unload
pressure
load pressure
motor start
motor
stop
motor
stop
motor start
motor
start