Electronic Controller
5.1.
General Operation
5.1.1.
Semi Automatic Mode (Standard Configuration)
Semi Automatic mode can be set in Operation Menu P01 after entering the user level access code. Semi Automatic
is a mode of operation in which the operator has control of when the compressor runs. The operator starts the
compressor by pressing the start button. When the pressure is below the unload pressure, the motor is started
immediately and the pressure will rise. The compressor will achieve the set unload pressure and then stop. The
compressor will only start again if the operator presses the start button again. In any case, the compressor stops
immediately when pressing the stop button.
Pressure
Time
internal pressure
delivery pressure
Low Pressure
Start Button
High
Pressure
High
Pressure
Trip Condition
or Stop
Sequence
Start Seq
Motor
Stop
Start Seq
Motor
Stop
Start Button
Start Button
Motor
Stop