Configuring the Unit Using the Internal Switches
4-9
7970-A2-GB20-00
August 1999
Switchpack Definitions for Models 7976 and 7986
Table 4-8 lists Switchpack S1 definitions.
Table 4-8.
Switchpack S1 Definitions (Models 7976 and 7986)
Switch # . . .
Allows you to . . .
Default in Bold
1
Enable or disable Switchpacks S1 and S2.
OFF = Switchpacks Disabled
ON = Switchpacks Enabled
2
Control line termination.
OFF = 120 Ohm
ON = 75 Ohm
3
Select the unit’s primary timing source. Only valid for units configured
as LTU.
OFF = Internal Clock
ON = External Clock
4
Control the unit’s E1 line coding.
OFF = HDB3
ON = AMI
5
Determine whether the unit will use G.704 framing.
OFF = Framed
ON = Unframed
6
Enable CRC-4 monitoring. Only valid for units configured as LTU. The
NTU will automatically be configured to match the LTU setting.
OFF = Disable CRC-4 monitoring
ON = Enable CRC-4
7
Control whether Channel 16 contains signaling information or data.
OFF = Channel 16 is used for signaling
ON = Channel 16 is used for data
8
Not used