Configuration Option Tables
A-18
7970-A2-GB20-00
August 1999
Table A-7.
Telnet Session Options
Telnet Session
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies if the unit will respond to a Telnet session request from a Telnet client on an
interconnected IP network.
Enable – Allows Telnet sessions between the unit and a Telnet client.
Disable – No Telnet sessions allowed.
Telnet Login Required
Possible Settings: Enable, Disable
Default Setting: Disable
Specifies whether a user ID and password are required to access to the ATI through a
Telnet session. Login IDs are created with a password and access level. Refer to
Creating a Login
in Chapter 8,
Security.
Enable – Security is enabled. When access is attempted via Telnet, the user is
prompted for a Login ID and password.
Disable – No Login required for a Telnet session.
Session Access Level
Possible Settings: Administrator, Operator
Default Setting: Administrator
The Telnet session access level is interrelated with the access level of the Login ID.
Refer to
ATI Access Levels
in Chapter 8,
Security for more information.
Administrator – This is the higher access level, permitting full control of the unit.
Access level is determined by the Login ID. If Telnet Login Required is disabled, the
session access level is Administrator.
Operator – This is the lower access level, permitting read-only access to status and
configuration screens.
Inactivity Timeout
Possible Settings: Enable, Disable
Default Setting: Disable
Provides automatic logoff of a Telnet session.
Enable – The Telnet session terminates automatically after the Disconnect Time. Set
the Disconnect time (in minutes) after enabling Inactivity Timeout.
Disable – A Telnet session will not be closed due to inactivity.
Disconnect Time (Minutes)
Possible Settings: 1 – 60
Default Setting: 5
Number of minutes of user inactivity before a Telnet session terminates automatically.
Time out is based on no keyboard activity.
H
Disconnect Time (minutes) appears only when the Inactivity Timeout option is
enabled.
1 to 60 – The Telnet session is closed after the selected number of minutes.
Summary of Contents for Hotwire 7974
Page 10: ...Contents vi 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Page 90: ...Testing 6 20 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Page 104: ...Security 8 8 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Page 154: ...Cables and Pin Assignments C 14 7970 A2 GB20 00 August 1999 This page intentionally left blank...
Page 156: ...Technical Specifications D 2 7970 A2 GB20 00 August 1999...