3. Status and Statistics
9000-A2-GB33-20
May 2003
3-33
CTS down to Port-1 Device
The user data port CTS control lead on the iMarc unit
is off.
DBM BRI Card Failed
(ISDN BRI DBM only)
One or more of the access unit’s integrated circuit
chips has failed to internally loop data through the
dial backup unit BRI circuit.
DBM Download Required
(ISDN BRI DBM only)
A download attempt was interrupted and failed to
complete.
The NAM software and DBM software are
incompatible.
DCLB Active,
[Interface]
A V.54 Loopback is active on the specified interface.
DLCI
nnnn
Down,
frame relay link
The DLCI for the specified frame relay link is down.
DSL Line Training Alarm at
Network 1
The DSL interface is training.
DTE External LB Active, Port-
n
A Data Terminal Loopback is running on the
specified user data port.
DTE Init. Ext LB Active, Port-
n
The DTE has initiated an external DTE Loopback on
the specified user data port.
DTPLB Active, Port-2
A Data Terminal Payload Loopback (DTPLB) is
active on the synchronous user data port.
DTR Down from Port-1 Device
The DTR control lead from the device connected to
the user data port is deasserted.
EER at ISDN PRI (Active/Idle)
(ISDN PRI DBM only)
The error rate of the received ISDN network signal
exceeds the currently configured threshold. This
condition only occurs if the network interface is
configured for ESF framing and a PRI dial backup
module (DBM) is installed.
Active – Backup call was in progress.
Idle – DBM was in Idle mode.
This condition clears when the error rate falls below
the threshold value, which may take up to
15 minutes.
EER at Network
1
The error rate of the received network signal
exceeds the currently configured threshold. This
condition only occurs if the network interface is
configured for ESF framing.
This condition clears when the error rate falls below
the threshold value, which may take up to
15 minutes.
Ethernet Mgmt Down
The Ethernet port is enabled, but communication
between the management system and the unit is not
currently possible on the port.
Ethernet Port Down
The Ethernet data link is down.
Table 3-6.
Health and Status Messages (2 of 7)
Message
What It Indicates