4. Operation and Maintenance
9000-A2-GB33-20
May 2003
4-5
Placing a Test Call (Nondisruptive)
Use this procedure to test the ISDN path to each remote site. This procedure will
not put the system into backup.
Procedure
1. Make sure the ISDN Link Profiles and DLCIs are set up correctly for the DBMs
at each end (see
Modifying ISDN Link Profiles
in the
iMarc SLV Configuration
Reference
.
Main Menu
→
Configuration
→
ISDN
→
Link Profiles
Main Menu
→
Configuration
→
ISDN
→
DLCI Records
2. Place a Test Call from one of the devices.
Main Menu
→
Test
→
ISDN Call/PVC Tests
— Select the link to be tested.
— Start a Test Call. The Status should be Active.
— Select Stop to end the Test Call.
Use this procedure to test the ISDN path to each remote site. This procedure will
not put the unit into backup.
If the Result is . . .
Then . . .
Frame Relay Link Up
The call was successful.
Frame Relay Link Down
The call was not successful. Verify the configuration and
Link Status in the ISDN Link Profile.