4. Configuration Options
4-54
December
2002
9700-A2-GB20-20
Initial Route Destination
Possible Settings:
AutoRoute, Ethernet, COM,
PVCname
Default Setting:
AutoRoute
Specifies the initial route used to reach the specified Trap Manager. When proprietary RIP
is active, only one unit in the network needs to specify an interface or management link as
the initial destination. All other units can use the default setting.
Display Conditions – This option appears for each trap manager specified in the
Number of Trap Managers configuration option.
AutoRoute
– Uses proprietary RIP from other FrameSaver devices to learn the route for
sending traps to the specified Trap Manager, or the Default IP Destination when no route
is available in the routing table (see
Table 4-18, Node IP Options
).
Ethernet
– Uses the Ethernet interface. Appears only when Interface Status for the
interface is enabled (see
Table 4-24, Ethernet Management Options
).
COM
– Uses the COM port. Only available when Port Use is set to Net Link (see
Table 4-25, Communication Port Options
).
PVCname
– Uses the defined management
linkname (the name given the Management
PVC). Appears only when at least one Management PVC is defined for the node.
General Traps
Possible Settings:
Disable, Warm, AuthFail, Both
Default Setting:
Both
Determines whether SNMP trap messages for warmStart and/or authenticationFailure
events are sent to the currently configured trap manager(s).
Disable
– Does not send trap messages for these events.
Warm
– Sends trap messages for warmStart events only.
AuthFail
– Sends trap messages for authenticationFailure events only.
Both
– Sends trap messages for both warmStart and authenticationFailure events.
Enterprise Specific Traps
Possible Settings:
Enable, Disable
Default Setting:
Enable
Determines whether trap messages for enterpriseSpecific events are sent to the currently
configured trap manager(s).
Enable
– Sends trap messages for enterpriseSpecific events.
Disable
– Does not send trap messages for enterpriseSpecific events.
Table 4-23. SNMP Traps Options (2 of 4)
Summary of Contents for FrameSaver 9720
Page 24: ...1 About FrameSaver DSL Devices 1 10 December 2002 9700 A2 GB20 20...
Page 34: ...2 User and Command Line Interfaces and Basic Operation 2 10 December 2002 9700 A2 GB20 20...
Page 104: ...4 Configuration Options 4 64 December 2002 9700 A2 GB20 20...
Page 224: ...9 Setting Up OpenLane for FrameSaver Device 9 10 December 2002 9700 A2 GB20 20...
Page 240: ...A Menu Hierarchy A 6 December 2002 9700 A2 GB20 20...
Page 318: ...E Connectors Cables and Pin Assignments E 14 December 2002 9700 A2 GB20 20...
Page 326: ...G Equipment List G 6 December 2002 9700 A2 GB20 20...