8. Troubleshooting
8-26
December
2002
9700-A2-GB20-20
Encapsulation
Available Settings:
Routed
Default Setting:
Routed
Specifies the IP encapsulation used by the data stream. This read-only field specifies that
the IP encapsulation used is RFC 1490/RFC 2427 routed Network Level Protocol
IDentifier (NLPID) encapsulation, and not SubNetwork Access Protocol (SNAP)
encapsulation.
Display Conditions – This setting does not appear when Destination Interface is set to
Use_Internal_Route.
Routed
– The encapsulation is routed NLPID.
TOS Byte
Available Settings:
A predefined COS ID, or a user-defined binary value 0000–1111
Default Setting:
User Defined – 000000
(Release 2.1.) Specifies the TOS (Terms Of Service) byte to be used with the ping packet.
Select from COS (Class Of Service) definitions, if any exist, or specify a binary value.
When a COS definition is selected, the TOS byte value is read-only. If you select a COS
definition that has multiple COS IDs, the lowest value is used as the TOS byte. See
Configuring Class of Service Definitions
in Chapter 4,
Configuration Options.
0000–1111
– The value of the TOS byte.
Packet Size
Available Settings:
36–4096
Default Setting:
100
Specifies the size of the ping packet including the IP header (20 bytes) and the ICMP
header (8 bytes).
1–4096
– Packet size.
Iteration Count
Available Settings:
1–999999
Default Setting:
5
Specifies the number of pings to send.
1–999999
– Number of pings.
Inter-Ping Delay
Available Settings:
1–900
Default Setting:
1
Specifies, in seconds, the amount of time to wait between pings.
1–900
– The ping wait time.
Response Timeout
Available Settings:
1–60
Default Setting:
2
Specifies the amount of time, in seconds, to wait before a host that has not responded to a
ping is declared unreachable.
1–60
– The response timeout period.
Table 8-5.
Ping Options (2 of 2)
Summary of Contents for FrameSaver 9720
Page 24: ...1 About FrameSaver DSL Devices 1 10 December 2002 9700 A2 GB20 20...
Page 34: ...2 User and Command Line Interfaces and Basic Operation 2 10 December 2002 9700 A2 GB20 20...
Page 104: ...4 Configuration Options 4 64 December 2002 9700 A2 GB20 20...
Page 224: ...9 Setting Up OpenLane for FrameSaver Device 9 10 December 2002 9700 A2 GB20 20...
Page 240: ...A Menu Hierarchy A 6 December 2002 9700 A2 GB20 20...
Page 318: ...E Connectors Cables and Pin Assignments E 14 December 2002 9700 A2 GB20 20...
Page 326: ...G Equipment List G 6 December 2002 9700 A2 GB20 20...