3. The system displays many message including the following significant ones:
Loading fonts
Loading configuration script
Loading packet driver
For further information on installation and startup –
Please refer to the C:\XONE\README or C:\EXODUS\README file.
Installation Completed
NOTE
For the 15000 platform, the division of full-feature workstations
among the three processors should be:
Host Uip-1 Uip-2
7 3 14
Configurations with fewer full-feature workstations should retain
equivalent ratios among the processors for best performance.
4. If the workstation is connected to an NMS host and while still in \EXODUS directory:
TYPE:
COPY HOST.CFG EXODUS.CFG
PRESS:
Enter
5. If the workstation is connected to a UIP and while still in the \EXODUS directory:
TYPE:
COPY UIP.CFG EXODUS.CFG
PRESS:
Enter
6.
TYPE:
edit EXODUS.CFG
PRESS:
Enter
The DOS editor displays the CFG file. Find the line which starts with
CONN_COMMAND and change WSNAME to the name of the workstation. Find the line
beginning with CONN_HOST and change NMSHOST to the name of the NMS host or
the UIP if this workstation will connect to the UIP. Save the file and exit the editor.